Section 4 • Repair Procedures
OPERATOR'S COMPARTMENT
How to Remove the Dash Cluster
Assembly
1 Open the access door above the hydraulic tank.
2 Disconnect the battery from the machine.
Electrocution hazard. Contact with
electrically charged circuits could
result in death or serious injury.
Remove all rings, watches and
other jewelry.
3 Remove the fasteners securing the
transmission control lever to the column.
Carefully separate the lever from the column.
4 Reach under the dashboard and gently push
the dash cluster through the opening in the
dashboard.
5 Tag and disconnect the wire harness from the
dash cluster. Remove the dash cluster from the
machine.
4 - 28
How to Remove the Diagnostic
Display
1 Open the access door above the hydraulic tank.
2 Disconnect the battery from the machine.
3 Reach under the dashboard and gently loosen
and remove the locknut securing the diagnostic
display to the dashboard. Gently push the
diagnostic display through the opening in the
dashboard.
4 Tag and disconnect the wire harness from the
diagnostic display. Remove the diagnostic
display from the machine.
GTH-1048 • GTH-1056
Electrocution hazard. Contact with
electrically charged circuits could
result in death or serious injury.
Remove all rings, watches and
other jewelry.
Part No. 123701