TOOLS NEEDED FOR INSTALLATION
• Saber Saw or Jig Saw
• Drill
• 1 1/4" Wood Drill Bit
• Scissors
• Pliers
• Phillips Screwdriver
• Flat Blade Screwdriver
• Wire Stripper or Utility Knife
• Metal Snips
• Measuring Tape or Ruler
• Level
• Pencil
• Caulking Gun
• Duct Tape
PARTS SUPPLIED FOR INSTALLATION
• 1 Hardware Package
• 1 Literature Package
PARTS NEEDED FOR INSTALLATION
• 2 Conduit Connectors
• Power Supply Cable
• 1 Wall or Roof Cap
• All Metal Ductwork
OPTIONAL ACCESSORIES AVAILABLE
• Glass Kit
25" deep by 36" wide glass "canopy" that mounts
to the bottom of the Cylindra
Part # GLSCYLNIS
• Charcoal Filter Kit
For non-vented installations only
* it is highly recommended that professional style
cooking always be vented to the outside
part #FILTER2
• CFM reduction kit
For make air up environments, converts the Cfm
of this hood to under 300 cfm
part #CFMRED
• Remote Control
Use a wireless remote to operate the rangehood
part #REMCTRL
PREPARING TO ATTACH THE CHIMNEY
The rangehood attaches to the ceiling by a metal
support structure (B in FIGURE 1). This support
must be attached to the ceiling before the hood is
attached. This structure must be firmly attached
to the ceiling.
FOR WOOD CEILINGS: Use four 4" long wood
screws and washers.
FOR PLASTER OR SHEET ROCK CEILINGS:
If possible, the support must be attached to the
ceiling joists. If not, a supporting structure behind
the sheet rock must be built.
PLAN THE INSTALLATION
This rangehood can be installed as either ducted or ductless. The blower
can be vented through the ceiling. When installed ductless, the rangehood
vents out of the sides of the chimney. Ductless installations require Charcoal
Filters, available from your dealer.
WARNING! BEFORE MAKING ANY CUTS OR HOLES FOR INSTALLATION,
DETERMINE WHICH VENTING METHOD WILL BE USED AND CAREFULLY
CALCULATE ALL MEASUREMENTS.
RANGEHOOD COMPONENTS
E
D
D
C
C
K
B
A
A
L
CALCULATE THE DUCTRUN LENGTH
For satisfactory performance the duct run should not exceed 50 equivalent
feet if ducted using the required minimum 6" round duct. Calculate the length
of the ductwork by adding the equivalent feet in FIGURE 2 for each piece of
duct in the system. An example is given in FIGURE 3.
45˚ Elbow
90˚ Elbow
90˚ Flat Elbow
12.0 feet
Wall Cap
FIGURE 2
For best results, use no more than three 90° elbows. Make sure that
there is a minimum of 24" of straight duct between elbows if more than
one is used. Do not install two elbows together. If you must elbow right
away, do it as far away from the hood's exhaust opening as possible.
G
F
H
J
I
A. CYLINDRA ISOLA HOOD
B. MOTOR & SUPPORT FRAME
C. CEILING SUPPORT SCREWS
D. WASHERS & NUTS
E. INSTALL TEMPLATE
F. DUCTLESS OUTLET
G. DUCTLESS OUTLET SCREWS
H. FLANGE
I. DAMPER
FIGURE 1
J. PIPE CLAMPS
K. REDUCER
L. HOOD INSTALL SCREWS
FIGURE 1
3.0 feet
9 Feet Straight Duct
5.0 feet
2 - 90˚ Elbows
Wall Cap
0.0 feet
Total System
FIGURE 3
9.0 feet
10.0 feet
0.0 feet
19.0 feet