Safety Distance (S) - Miele DA 6690 W Operating And Installation Instructions

Table of Contents

Advertisement

a Extraction
b Recirculation
c Ventilation grille positioned at the top for recirculation
de (only d is required for recirculation mode rangehoods): The shaded area
represents the wall or ceiling area for the vent cut-out, for fitting the
connection socket and on EXT models for feeding the connection cable
through to the external motor. Recirculation mode rangehoods only require
an electrical connection socket.
Connection for air extraction  150 mm, or 125 mm with reducing collar.

Safety distance (S)

The minimum distances between the highest part of a cooktop (including
trivets, dials - depending on model) and the bottom of the rangehood are as
follows, unless a greater distance is specified by the manufacturer of your
cooking appliance.
See also "Warning and Safety instructions".
Cooking appliance
Electric cooktop
Electric grill, deep fat fryer (electric)
Multi-burner gas cooktop with maximum 45.4 MJ/h total output,
with no burner having a greater output than 16.2 MJ/h.
Multi-burner gas cooktop with total output greater than 45.4 MJ/h,
but with a maximum of 77.8 MJ/h, with no burner having a greater
output than 17.3 MJ/h.
Multi-burner gas cooktop with total output greater than 77.8 MJ/h,
with a single burner having a greater output than 17.3 MJ/h.
Single burner gas cooktop with a maximum output of 21.6 MJ/h.
Single burner gas cooktop with an output greater than 21.6 MJ/h,
but with a maximum of 29.2 MJ/h.
Single burner gas cooktop with an output greater than 29.2 MJ/h.
Installation
Minimum
distance S
600 mm
650 mm
650 mm
760 mm
Not
possible
650 mm
760 mm
Not
possible
37