Operating hours counter

The number of hours the appliance has
been in operation is stored in memory.
When the grease filter symbol  or the
charcoal filter symbol  lights up, the
operating hours counters are signalling
that the filters need to be cleaned or
changed. Further information about
cleaning and changing the filters and
resetting the operating hours counter
can be found under "Cleaning and
care".
Altering the operating hours counter
for the grease filters
You can set the operating hours counter
for the grease filters to suit the type of
cooking you do.
It is set at the factory for 30 hours.
– Select a shorter time (20 hours) if you
fry a lot.
– If you only cook occasionally, we
recommend that you still select a
short time because grease which has
built up gradually over a long period
of time will harden on the filters and
make cleaning more difficult.
– If you use very little fat for cooking,
select a longer time (40-50 hours).
 Press the On/Off touch control  to
switch the fan off.
 Touch the run-on option control 
and the grease filter control  at the
same time.
The grease filter symbol  and one of
the fan power setting indicators will
flash.

Operation (automatic and manual modes)

Fan power setting indicators 1 to IS
show the time set:
1............................................... 20 hours
2............................................... 30 hours
3............................................... 40 hours
IS ............................................. 50 hours
 Touch the relevant control to select
the duration required.
 Confirm the selection by touching the
grease filter control .
All the indicator lights will go out.
If you don't confirm your selection
within 4 minutes, the rangehood will
automatically revert to the previous
setting.