Appliance Dimensions; Safety Distance (S) - Miele DA 5690 W Operating And Installation Instructions

Table of Contents

Advertisement

1) Extraction
2) Recirculation
3) Ventilation grille positioned at the top
for recirculation
4) and 5):
(5 is not required for recirculation mode
cooker hoods)
The shaded area represents the wall or
ceiling area for the vent cut-out, for
fitting the connection socket and on
EXT models for feeding the connection
cable through to the external motor.
For recirculation mode, only a
connection socket needs to be fitted.
Connection for air extraction
C 150 mm, or C 125 mm with reducing
collar.

Appliance dimensions

Safety distance (S)

When planning the installation
height of your cooker hood, the
minimum safety distance between
the top of a cooker or hob and the
bottom of the cooker hood are as
follows, unless a greater distance is
specified by the manufacturer of
your cooking appliance:
450 mm (GB), 600 mm (AU, NZ)
above electric hobs and cookers,
650 mm above an open grill or deep
fat fryer,
650 mm above gas hobs and cookers.
If this cooker hood is installed above a
Miele Wok CS 1028 CombiSet
appliance, a minimum safety distance
of 760 mm must be maintained
between the burner and the lower
edge of the cooker hood.
See "Warning and Safety" instructions
for further information.
– When deciding on the safety
distance, please note that 650 mm
may be preferable above electric
cookers/hobs to give more working
space.
– Account should also be taken of the
height of the person who will be
using the hood most often. They
should have sufficient space to work
comfortably at the hob, and be able
to reach the hood controls with ease.
– If positioned too high, extraction will
be inefficient.
– The height of the cooking appliance
below must be taken into account
when planning the installation height
of the cooker hood.
25