Installation Instructions
DA6690 D
en - CA
Installation, repair and maintenance work should be performed by
a Miele authorized service technician in accordance with national
and local safety regulations and the provided installation instructions.

Advertisement

Table of Contents
loading

Summary of Contents for Miele DA6690 D

  • Page 1 Installation Instructions DA6690 D en - CA Installation, repair and maintenance work should be performed by a Miele authorized service technician in accordance with national and local safety regulations and the provided installation instructions.
  • Page 2: Before Installation

    Installation Before installation  Before installing the appliance, read all of the information contained in this chapter and also in the "IM‐ 4 extension piece holders PORTANT SAFETY INSTRUCTIONS" for aligning and securing the telescopic section. chimney Installation parts 4 screws M³/₁₆" x ⁵/₁₆" (M4 x 8.5 mm) for securing the extension piece hold‐...
  • Page 3: Appliance Dimensions

    Installation Appliance dimensions a Mounting area for the exhaust ducting and power cable. In recirculation mode, only the power cord is required. b Possible height range for appliance in vented mode c Possible height range for appliance in recirculation mode d Alternative installation with spacer frame e Air vent positioned at the top for recirculation...
  • Page 4: Distance Between Cooktop And Ventilation Hood (S)

    Please also observe the information contained in the "IMPORTANT SAFETY IN‐ STRUCTIONS" section. Minimum distance S Cooking appliance Miele Non-Miele appliance appliance Electric/Induction cooktop 24" (610 mm) Electric grill, deep fat fryer (electric) 26"...
  • Page 5: Installation Recommendations

    Installation Installation recommendations Structural support – We also recommend a distance of at least 25 ¹/₂" (650 mm) above electric cooktops to provide more workspace and easier cooking under the hood. – When selecting an installation height, always take the user height into con‐ sideration.
  • Page 6 Installation " "  For vented mode: – Place a section of the exhaust duct‐ ing in the ceiling and feed it down through the cross-sectional area as illustrated. Exhaust ducting of ap‐ prox. 27 ⁹/₁₆" (700 mm) length is re‐ dai3435aus quired between the ceiling and the hood exhaust socket.
  • Page 7 Installation  Use a knife to release the four spacers and the two covers from the spacer frame supplied.  Drill four holes  ³/₈" (10 mm), ap‐ prox. 4 ¹/₂" (115 mm) deep for the plugs supplied.  Place the four plugs in the holes and ...
  • Page 8 Installation The spacer frame can be installed be‐ tween the chimney and the ceiling. This creates a shadow which gives the illu‐ sion of a gap between the ceiling and the chimney. This is useful if the ceiling  Mount the spacer frame onto the in‐ is not level or is uneven.
  • Page 9 Installation  Hang the installation frame on the  Align the installation frame and se‐ four screws. The front of the frame is cure it with the screws. marked with a "V". The spacers, which were removed  If using the spacer frame, place the from the spacer frame at the start, two covers into the fixing holes.
  • Page 10 Installation  Holding the installation frame secure‐ ly, remove the two fixing screws and extend the installation frame to its maximum length.  Replace the screws. The directional unit from recirculation kit DUI 32 (optional accessory) is instal‐ led for recirculation mode (RM): ...
  • Page 11 Installation  Secure the exhaust socket to the hose using a hose clip.  Secure the hose to the directional unit socket using a hose clip.  Check that the hose is held securely.  Push the telescopic chimney over the installation frame: –...
  • Page 12 Installation  Fit the four telescopic chimney  Bend back the two retaining tabs. clamps. When the screws are tight‐  Push the chimney over the telescopic ened, the clamps spread out and chimney and bend the retaining tabs push the telescopic expansion piece outwards again to prevent the chim‐...
  • Page 13 Installation A non-return flap is supplied with the hood or is already fitted in the exhaust socket of the motor unit (depending on model).  With vented mode (AE) insert the non-return flap in the exhaust socket if your ducting system is not equip‐ ped with one.
  • Page 14 Installation  Connect the power cord. See "Elec‐ trical connection."  Unscrew both screws from the instal‐ lation frame again.  Place the exhaust ducting onto the The canopy can now be adjusted to the exhaust socket. desired height, observing the permissi‐ ble height ranges: –...
  • Page 15 Installation  Hold the chimney securely, bend  Raise the canopy to the desired height and secure it with the screws. back the retaining tabs and carefully lower it. The chimney will locate in the cut-out in the canopy.
  • Page 16 Installation  With recirculation mode (RM) ventila‐ tion hoods, insert the OdorFree Char‐ coal Filter.  Remove the grease filters from the hood.  Insert the safety screw on the inside.  Carefully remove the protective foil from the grease filters. ...
  • Page 17: Exhaust Duct

    Exhaust duct WARNING: Danger of toxic fumes. Remember that any constriction of Gas cooking appliances release car‐ the airflow will reduce extraction per‐ bon monoxide that can be harmful or formance and increase operating fatal if inhaled. noise. To reduce the risk of fire and to prop‐ ...
  • Page 18: Condensate Trap

    Exhaust duct Condensate trap In addition to insulating the exhaust duct, we recommend installing a con‐ densate trap to collect and evaporate any condensate which might accumu‐ late. Condensate traps are available for ex‐ haust ducts with a diameter of 5" (125 mm) or 6"...
  • Page 19: Electrical Connection

    If there is any question concerning the electrical connection of this ap‐ pliance to your power supply, please consult a licensed electrician or call Miele’s Technical Service Depart‐ ment. WARNING: THIS APPLIANCE MUST BE GROUNDED...
  • Page 20 Activating Con@ctivity 2.0 Installation of the Con@ctivity Activating the ventilation hood 2.0 stick  The cooktop and hood must be turned off. In order for you to be able to use the Con@ctivity 2.0 function, the cooktop  Press the delayed shut down button must be equipped with a Con@ctivity ...
  • Page 21 Activating Con@ctivity 2.0 Activating the cooktop Activation failed  While the ventilation hood is search‐  If a wireless connection cannot be ing for a wireless connection, start established despite activation of the activation on the cooktop. Con@ctivity function on the ventila‐ More information can be found in the tion hood and cooktop, the function operating instructions for the cook‐...
  • Page 22: Service And Warranty

    Service and warranty For faults that you cannot resolve on your own, please contact your Miele dealer or Miele Technical Service. The telephone number for the Technical Service Department is listed at the back of these instructions. When contacting Miele, please state the model and serial number of your ventilation hood.
  • Page 23: Technical Data

    Technical data Fan motor 350 W Overhead lighting 4 x 3 W Total connected load 362 W Voltage, Frequency 120 V AC, 60 Hz Fuse rating 15 A Power cord length 6.5 ft. (2 m) Weight 77 lbs (35 kg) Optional accessories for recirculation mode: Recirculation kit DUW 32 and OdorFree Charcoal Filter DKF 12 Contains...