Summary of Contents for Miele DA 6690 D

  • Page 1 Operating and Installation Instructions Ventilation Hood To prevent accidents and damage to the appliance, you must read these instructions before installing the appliance and using it for the first time. en-US M.-Nr. 09 805 980...
  • Page 2: Table Of Contents

    Contents IMPORTANT SAFETY INSTRUCTIONS..............4 Caring for the environment ................. 13 Description of functions ..................14 Con@ctivity 2.0 function ..................15 Guide to the appliance..................16 Operation (Automatic mode)................18 Cooking with Con@ctivity 2.0 (Automatic mode)........... 18 Temporarily exiting Automatic mode ..............20 Resuming Automatic mode ...................
  • Page 3 Contents Removing the protective film ................. 34 Exhaust duct......................46 Condensate trap ....................47 Electrical connection ................... 48 Grounding Instructions ..................48 Activating Con@ctivity 2.0 ................... 49 Installation of the Con@ctivity 2.0 stick ..............49 Activating the Con@ctivity 2.0 function ..............49 Activating the ventilation hood .................
  • Page 4: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS This appliance complies with current safety requirements. Improp‐ er use of the appliance can lead to personal injury and material damage. Read all instructions before installing or using the appliance for the first time. Only use the appliance for its intended purpose. Keep these operating instructions in a safe place and pass them on to any future user.
  • Page 5: Technical Safety

     Installation, repair and maintenance work should be performed by a Miele authorized service technician in accordance with national and local safety regulations and the provided installation instruc‐ tions. Contact Miele’s Technical Service Department for examina‐...
  • Page 6 IMPORTANT SAFETY INSTRUCTIONS  Be certain your appliance is properly installed and grounded by a qualified technician. To guarantee the electrical safety of this appli‐ ance, continuity must exist between the appliance and an effective grounding system. It is imperative that this basic safety requirement be met.
  • Page 7: Proper Use

    IMPORTANT SAFETY INSTRUCTIONS  Defective components should be replaced by Miele original parts only. Only with these parts can the manufacturer guarantee the safe‐ ty of the appliance.  During installation, maintenance, and repair work, the ventilation hood must be disconnected from the electrical supply. It is only...
  • Page 8 IMPORTANT SAFETY INSTRUCTIONS  WARNING: TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A COOKTOP GREASE FIRE, OBSERVE THE FOL‐ LOWING*: – a) SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray then turn off the burner. BE CAREFUL TO PREVENT BURNS.
  • Page 9 IMPORTANT SAFETY INSTRUCTIONS  Overheated oils and fats can ignite and set the ventilation hood on fire. When cooking with oils or fats, do not leave pots, pans or fryers un‐ attended. Never leave an electric grill unattended when grilling. ...
  • Page 10 IMPORTANT SAFETY INSTRUCTIONS Proper installation  WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: – a) Installation work and electrical wiring must be done by quali‐ fied person(s) in accordance with all applicable codes and stand‐ ards, including fire-rated construction.
  • Page 11 Wear gloves to protect your hands from being cut.  When installing the exhaust duct, only use pipes or tubes made of non-flammable material. These can be obtained from your Miele dealer or from Miele Technical Service.  Exhaust air should not be vented into a chimney or vent flue which is otherwise in use and should not be channeled into ducting which ventilates rooms with fuel-burning installations.
  • Page 12: Cleaning And Care

    The steam can reach the electrical components and cause a short circuit. Accessories  Use only genuine original Miele parts. If parts or accessories from other manufacturers are used, the warranty will become void. FCC Declaration of Conformity  These devices comply with FCC Rules Part 15. This equipment has been tested and found to be in compliance with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules of Oper‐...
  • Page 13: Caring For The Environment

    Caring for the environment Disposal of the packing mate‐ Disposal of your old appliance rial Do not dispose of this appliance with your household waste. The cardboard box and packing materi‐ als protect the appliance during ship‐ Old appliances may contain materials ping.
  • Page 14: Description Of Functions

    Description of functions The following functions are available on Recirculation mode your ventilation hood, depending on the The recirculation mode requires a recir‐ model: culation kit and OdorFree Charcoal Fil‐ ter (available as optional accessories, Vented mode see "Technical Data" for more informa‐ tion) The air is drawn in and cleaned by the grease filters and directed outside.
  • Page 15: Con@Ctivity 2.0 Function

    After a brief delay, tional status of a Miele cooktop. the ventilation hood fan also comes – During cooking, the hood automati‐ cally selects the fan level based on the number of burners in operation and their power levels.
  • Page 16: Guide To The Appliance

    Guide to the appliance...
  • Page 17: Guide To The Appliance

    Guide to the appliance a Chimney extension b Chimney c Canopy d Control panel The symbols act as sensor-controlled buttons. To select a function, tap the button. An audible tone sounds briefly to confirm selection. e Grease filter f Spacer frame The spacer frame creates a shadow gap between the chimney and the ceiling.
  • Page 18: Operation (Automatic Mode)

    Operation (Automatic mode) When Con@ctivity 2.0 is active, the Reaction time hood always operates in Automatic Changing the power setting on the mode (see "Activating Con@ctivity cooktop does not lead to an immediate 2.0"). increase or decrease in cooking vapors. See "Cooking without Con@ctivity 2.0"...
  • Page 19 Operation (Automatic mode) Cooking process Turning off  If, for example, you switch on a burn‐  Turn off all burners. er at the highest power setting to Over the next few minutes, the ventila‐ heat cookware in preparation for tion hood fan setting will decrease one searing and then reduce the power level at a time until the hood eventually...
  • Page 20: Temporarily Exiting Automatic Mode

    Operation (Automatic mode) Temporarily exiting Automatic Resuming Automatic mode mode The ventilation hood resumes Automat‐ ic mode: To temporarily exit the Automatic mode when cooking:  If the ventilation hood has not been used for a period of approx. 5 mi‐ ...
  • Page 21: Operation (Manual Mode)

    Operation (Manual mode) Cooking without Con@ctivity Selecting the delayed shut 2.0 (Manual mode) down time The hood can be operated manually if: It is a good idea to let the fan run for a few more minutes after cooking in order –...
  • Page 22: Turning Overhead Lighting On/Off

    Operation (Manual mode) Turning overhead lighting  Tap 1 to turn off the power manage‐ ment. on/off The 1 and IS indicators will flash. The overhead lighting can be turned on and off separately from the fan.  Touch IS to turn it on. ...
  • Page 23: Operation (Automatic And Manual Modes)

    Operation (Automatic and Manual modes) Filter saturation indicator The indicators 1 to IS show the current time setting: The number of hours the hood has Indicator 1 ....... 20 hours been in operation is stored in appliance memory. Indicator 2........ 30 hours The filter saturation indicators show Indicator 3........
  • Page 24: Activating/Changing The Odorfree Charcoal Filter Operating Hours Counter

    Operation (Automatic and Manual modes) Activating/changing the OdorFree Checking the filter saturation indica‐ Charcoal Filter operating hours counter Before the set operating time has run The OdorFree Charcoal Filter is required out, you can check what percentage of for extraction mode. the time has elapsed.
  • Page 25: Sensor Button Signal Tone

    Operation (Automatic and Manual modes) Sensor button signal tone Whenever you select a feature with the sensor buttons, you will hear a brief sig‐ nal tone. You can deactivate this signal tone if you prefer.  Press the On/Off button  to turn the fan off.
  • Page 26: Cleaning And Care

     Before cleaning or servicing the less steel cleaner, available from hood, disconnect it from the power Miele. supply, see "IMPORTANT SAFETY INSTRUCTIONS".  To prevent the surfaces from quickly becoming dirty again, we recom‐...
  • Page 27: Special Instructions For Glass Surfaces

    Cleaning and care Special instructions for control but‐  You can adjust the interval of the filter tons saturation counter to match your cooking habits (see "Operation"). Do not leave dirt and debris on the buttons for any length of time. Removing the grease filters Otherwise they may become discol‐...
  • Page 28  To remove a grease filter, release the perature between 122°F (50°C) and locking clip. Then, open the filter to a 149°F (65°C). In a Miele dishwasher 45° angle, unhook it, and remove it use the "Normal" program. from the hood.
  • Page 29: Odorfree Charcoal Filter

    Once cleaning is complete, the filter OdorFree Charcoal Filters are available saturation indicator must be reset. from your Miele dealer or from Miele.  While the fan is turned on, press the See "Technical data" for the type and grease filter button  for approx. 3 reference number.
  • Page 30: Resetting The Operating Hours Counter For The Odorfree Charcoal Filter

    Cleaning and care When to change the OdorFree Char‐ coal Filter  Always replace the OdorFree Char‐ coal Filter whenever it no longer ab‐ sorbs kitchen odors effectively. Replace the filter at least once every 6 months. The OdorFree Charcoal Filter saturation counter ...
  • Page 31: Installation

    Installation Before installation  Before installing the appliance, read all of the information contained in this chapter and also in the "IM‐ 4 extension piece holders PORTANT SAFETY INSTRUCTIONS" for aligning and securing the telescopic section. chimney Installation parts 4 screws M3/16" x 5/16" (M4 x 8.5 mm) for securing the extension piece hold‐...
  • Page 32: Appliance Dimensions

    Installation Appliance dimensions a Mounting area for the exhaust ducting and power cable. In recirculation mode, only the power cord is required. b Possible height range for appliance in vented mode c Possible height range for appliance in recirculation mode d Alternative installation with spacer frame e Air vent positioned at the top for recirculation...
  • Page 33: Distance Between Cooktop And Ventilation Hood (S)

    Please also observe the information contained in the "IMPORTANT SAFETY IN‐ STRUCTIONS" section. Minimum distance S Cooking appliance Miele appli‐ Non-Miele ap‐ ance pliance Electric/Induction cooktop 24" (610 mm) Electric grill, deep fat fryer (electric) 26"...
  • Page 34: Installation Recommendations

    Installation Installation recommendations Structural support – We also recommend a distance of at least 25 1/2" (650 mm) above electric cooktops to provide more workspace and easier cooking under the hood. – When selecting an installation height, always take the user height into con‐ sideration.
  • Page 35 Installation " "  For vented mode: – Place a section of the exhaust duct‐ ing in the ceiling and feed it down through the cross-sectional area as illustrated. Exhaust ducting of ap‐ prox. 27 9/16" (700 mm) length is re‐ dai3435aus quired between the ceiling and the hood exhaust socket.
  • Page 36 Installation  Use a knife to release the four spacers and the two covers from the spacer frame supplied.  Drill four holes  3/8" (10 mm), ap‐ prox. 4 1/2" (115 mm) deep for the plugs supplied.  Place the four plugs in the holes and ...
  • Page 37 Installation The spacer frame can be installed be‐ tween the chimney and the ceiling. This creates a shadow which gives the illu‐ sion of a gap between the ceiling and the chimney. This is useful if the ceiling  Mount the spacer frame onto the in‐ is not level or is uneven.
  • Page 38 Installation  Hang the installation frame on the  Align the installation frame and se‐ four screws. The front of the frame is cure it with the screws. marked with a "V." The spacers, which were removed  If using the spacer frame, place the from the spacer frame at the start, two covers into the fixing holes.
  • Page 39 Installation  Holding the installation frame secure‐ ly, remove the two fixing screws and extend the installation frame to its maximum length.  Replace the screws. The directional unit from recirculation kit DUI 32 (optional accessory) is instal‐ led for recirculation mode (RM): ...
  • Page 40 Installation  Secure the exhaust socket to the hose using a hose clip.  Secure the hose to the directional unit socket using a hose clip.  Check that the hose is held securely.  Push the telescopic chimney over the installation frame: –...
  • Page 41 Installation  Fit the four telescopic chimney  Bend back the two retaining tabs. clamps. When the screws are tight‐  Push the chimney over the telescopic ened, the clamps spread out and chimney and bend the retaining tabs push the telescopic expansion piece outwards again to prevent the chim‐...
  • Page 42 Installation A non-return flap is supplied with the hood or is already fitted in the exhaust socket of the motor unit (depending on model).  With vented mode (AE) insert the non-return flap in the exhaust socket if your ducting system is not equip‐ ped with one.
  • Page 43 Installation  Connect the power cord. See "Elec‐ trical connection."  Unscrew both screws from the instal‐ lation frame again.  Place the exhaust ducting onto the The canopy can now be adjusted to the exhaust socket. desired height, observing the permissi‐ ble height ranges: –...
  • Page 44 Installation  Hold the chimney securely, bend  Raise the canopy to the desired height and secure it with the screws. back the retaining tabs and carefully lower it. The chimney will locate in the cut-out in the canopy.
  • Page 45 Installation  With recirculation mode (RM) ventila‐ tion hoods, insert the OdorFree Char‐ coal Filter.  Remove the grease filters from the hood.  Insert the safety screw on the inside.  Carefully remove the protective foil from the grease filters. ...
  • Page 46: Exhaust Duct

    Exhaust duct WARNING: Danger of toxic fumes. Remember that any constriction of Gas cooking appliances release car‐ the airflow will reduce extraction per‐ bon monoxide that can be harmful or formance and increase operating fatal if inhaled. noise. To reduce the risk of fire and to prop‐ ...
  • Page 47: Condensate Trap

    Exhaust duct Condensate trap In addition to insulating the exhaust duct, we recommend installing a con‐ densate trap to collect and evaporate any condensate which might accumu‐ late. Condensate traps are available for ex‐ haust ducts with a diameter of 5" (125 mm) or 6"...
  • Page 48: Electrical Connection

    If there is any question concerning the electrical connection of this ap‐ pliance to your power supply, please consult a licensed electrician or call Miele’s Technical Service Depart‐ ment. WARNING: THIS APPLIANCE MUST BE GROUNDED...
  • Page 49: Activating Con@Ctivity 2.0

    Activating Con@ctivity 2.0 Installation of the Con@ctivity Activating the ventilation hood 2.0 stick  The cooktop and hood must be turned off. In order for you to be able to use the Con@ctivity 2.0 function, the cooktop  Press the delayed shut down button must be equipped with a Con@ctivity ...
  • Page 50: Activating The Cooktop

    Activating Con@ctivity 2.0 Activating the cooktop Activation failed  While the ventilation hood is search‐  If a wireless connection cannot be ing for a wireless connection, start established despite activation of the activation on the cooktop. Con@ctivity function on the ventila‐ More information can be found in the tion hood and cooktop, the function operating instructions for the cook‐...
  • Page 51: Service And Warranty

    Service and warranty For faults that you cannot resolve on your own, please contact your Miele dealer or Miele Technical Service. The telephone number for the Technical Service Department is listed at the back of these instructions. When contacting Miele, please state the model and serial number of your ventilation hood.
  • Page 52: Technical Data

    Technical data Fan motor 350 W Overhead lighting 4 x 3 W Total connected load 362 W Voltage, Frequency 120 V AC, 60 Hz Fuse rating 15 A Power cord length 6.5 ft. (2 m) Weight Optional accessories for recirculation mode: Recirculation kit DUW 32 and OdorFree Charcoal Filter DKF 12 Contains FCC ID: 2ACUWEI8800...
  • Page 55 Technical Service. U.S.A. Canada Miele, Inc. Importer Miele Limited National Headquarters 9 Independence Way Headquarters and Miele Centre Princeton, NJ 08540 161 Four Valley Drive 800-843-7231 Phone: Vaughan, ON L4K 4V8 609-419-9898 www.miele.ca 609-419-4298...
  • Page 56 DA 6690 D  en-US M.-Nr. 09 805 980 / 00...

This manual is also suitable for: