Starter command P0170 - shorted to positive.

Error cause

Shorted to positive: excessive voltage at PIN 10 of the control unit connector.

Troubleshooting

Shorted to positive:
This malfunction is detected with a brake activated and the starter button pressed (voltage
of 12V read at PIN 6).
If the battery voltage does not drop (thanks to the absorption of the No. 6 starter command
relay excitation coil) the control unit understands that PIN 10 is shorted to battery.
Restore the cabling (if the short is in the cabling) or the relay (if the short is in the relay).
NOTE
IN CASE OF SHORT TO GROUND / OPEN CIRCUIT NO ERROR WILL APPEAR: SEE THE TROU-
BLESHOOTING CHAPTER, THE ENGINE DOES NOT START.

level indicators

Petrol pump:
Input 4A (to be measured between pins 1 and 2
with 12V supply voltage)
Fuel level sensor:
Resistance 1.4 Ohm (to be measured between
pins 3 and 4 with fuel level equal to 0 litres)

Lights list

Specification
Low/high beam light (halogen)
Front daylight running lights
Turn indicator light
License plate light
tail light /stop lights
Dashboard lighting
BULBS
Desc./Quantity
12 V - 55 W / 60 W H4
12 V - 10 W (orange RY 10 W bulb)
Electrical system
12V - 5W
12V - 5 W
12 V - 5 / 21 W
LED
ELE SYS - 97