Service Procedures
should be set to appropriate value in
table below
Refrigerator Cut-In
Model
5421
5481
Using Higher and Lower pads set to correct
value as in illustration below.
Press and release "FRZ TEMP",
this will result in "FREEZER"
illuminating on display.
The freezer section should be set to
appropriate value in table below.
Freezer Cut-In
Model
5421
5481
Using Higher and Lower pads set to correct
value as in illustration below.
To exit the cut-in adjustment press and
release "ACTIVATE CONTROLS" one time
which will result in "PrA" being displayed. You
are now back in Mode A.
32
Value
6
6
FRZ
TEMP
HIGHER
Value
LOWER
7
7

Adjust Cut-Out Hysteresis

Cut-Out hysteresis for the refrigerator and
freezer is set to predetermined values, based
upon model of refrigerator. This value can
be set in Mode A as a separate adjustment
or can be set automatically in Mode B when
selecting model code, where several control
values are set by eeprom.Table 1 on Page 42
lists eeprom values set by model code.
While still in Mode A press and hold
"ALARM OFF" and then"LOWER"
pad at the same time for three
seconds, the display will change to
"COH".
Press "REF TEMP to select
the refrigerator compartment,
the display will illuminate
"REFRIGERATOR" on display.
Next Press and release "HIGHER
or LOWER" which will result in
displaying degrees in Fahrenheit.
For the refrigerator section this
should be set to appropriate value
in table below.
Refrigerator Cut-Out
Model
5421
5481
Using Higher and Lower pads set to correct
value as in illustration below.
ALARM
HIGHER
LOWER
Value
-6
-6
©2012 Viking Preferred Service
OFF
HIGHER
REF
TEMP

Hide quick links: