M: Wireless Flash Shooting With Manual Flash; Multi: Wireless Flash Shooting With Manual Flash; Wireless Flash Shooting: Radio (2.4G) Transmission - Godox V860 Instruction Manual

Hide thumbs Also See for V860:
Table of Contents

Advertisement

The flash ratio of 8:1 to 1:1 to 1:8 is equivalent to 3:1 to 1:1
to 1:3 (1/2 step increment).
● The details of the flash ratio settings are as follows.
8:1
4:1
2:1
5.6:1
2.8:1
1.4:1

6. M: Wireless Flash Shooting with Manual Flash

This describes wireless (multiple shooting) using manual flash. You
can shoot with a different flash output setting for each slave unit
(firing group). Set all parameters on the master unit.
When ALL < RATIO OFF > is set, set A, B or C as the firing
group for the slave units.
To fire multiple slave units with the same flash output,
select ALL < RATIO OFF > in step 2.
Setting <M> Flash Mode
You can directly operate the slave unit to manually set the manual
flash or stroboscopic flash.
- 51 -
1:1
1:2
1:4
1:8
1:1.4
1:2.8
1:5.6
1
Setting the flash mode to
<M>.
2
Setting the number of flash
groups.
● When <
> is
MENU1
displayed, press the
Function Button 2
<
RATIO
> to set the
groups to fire.
● The setting changes as
follows each time you
press the button:
ALL(RATIO OFF)→
A/B(RATIO A:B)→
A/B/C(RATIO A:B:C)
3
Setting flash output.
● Press Function Button 3
<
>. Turn the Select
Gr
Dial to set the flash output
of the groups. Press
<SET> button to confirm.
4
Taking the picture.
● Each group fires at the set
flash ratio.
1
Setting the slave unit.
(Page 46)
2
Setting flash mode to <M>.
● Press <MODE> button so
that <M> is displayed.
● Set the manual flash
output. (Page 43)

7. Multi: Wireless Flash Shooting with Manual Flash

The firing frequency of stroboscopic flash during the optic
transmission wireless shooting can be set from 1Hz to 199Hz
(settings from 250 Hz to 500 Hz are not available).

Wireless Flash Shooting: Radio (2.4G) Transmission

Using a flash (master/slave) with a radio transmission wireless
shooting function make it easy to shoot with advanced wireless
multiple flash lighting, in the same way as E-TTL II autoflash
shooting.
The basic relative position and operation range are as shown in the
picture. You can then perform wireless E-TTL II /ETTL autoflash
shooting just by setting the master unit to <ETTL>.
Positioning and Operation Range (Example of wireless flash
shooting)
● Autoflash Shooting with One Slave Unit
● Use the supplied mini stand to position the slave unit.
● Before shooting, perform a test flash and test shooting.
● The transmission distance might be shorter depending on
the conditions such as positioning of slave units, the
surrounding environment and whether conditions.
Wireless Multiple Flash Shooting
You can divide the slave units into two or three groups and perform
E-TTL II/E-TTL autoflash while changing the flash ratio (factor). In
addition, you can set and shoot with a different flash mode for each
firing group, for up to 5 groups.
● Auto Shooting with Two Slave Groups
Setting <MULTI> stroboscopic
flash.
● Press <MODE> button so that
<MULTI> is displayed.
● Setting the stroboscopic flash.
(Page 44)
Transmission distance is about 100m.
- 52 -

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tt685

Table of Contents