Enter key
This key allows you to enter data into the console
computer.
CE key
This key clears the data shown in the display; it also
enables you to toggle through the options found in
certain function keys.
The Console Keys
The keypad for the console computer is shown in Figure 13.
BOOM 1
BOOM 2
CAL
CAL
1
2
TOTAL
CE
AREA
Keypad Reference Table
Key
Description
BOOM 1
Length of boom 1
CAL
BOOM 2
Length of boom 2
CAL
BOOM 3
Length of boom 2
CAL
SPEED
Speed calibration number
CAL
METER
Flowmeter calibration number
CAL
VALVE
Control valve response time
CAL
RATE 1
Target application rate 1
CAL
RATE 2
Target application rate 2
CAL
VOL /
Volume of material remaining in the
TANK
tank
TIME
24-hour clock
SELF
Simulation of vehicle speed
TEST
BOOM 3
SPEED
METER
CAL
CAL
CAL
3
4
5
TOTAL
FIELD
FIELD
VOLUME
AREA
VOLUME
Value
Backspace It simulates the vehicle speed to allow the operator to check and
The console computer allows the following parameters:
• Area: US (acres); SI (hectares) or TU (1000 ft
• Speed sensor type: SP1 (wheel drive, etc.), SP2
(radar), or SP3. This system uses the SP3 gear tooth
sensor. Refer to Initially Programming the Console
Computer on page 7.
VALVE
RATE 1
CAL
CAL
7
6
SPEED
DISTANCE
Figure 13
1
It calculates the length of the boom by multiplying the
number of nozzles by the spacing between them in
inches (cm) of the left boom.
Enter 80 inches (204 cm) as the default.
2
It calculates the length of the boom by multiplying the
number of nozzles by the spacing between them in
inches (cm) of the center boom.
Enter 60 inches (152 cm) as a default.
3
It calculates the length of the boom by multiplying the
number of nozzles by the spacing between them in
inches (cm) of the right boom.
Enter 80 inches (204 cm) as a default.
4
It enables you to verify that the vehicle distance readout is accurate.
Enter 148 as a starting point for all Toro sprayers.
5
Enter the number found on the flowmeter label or the tag on the
flowmeter cable.
6
It sets the system response.
Enter 023 as a starting point. Note: 0 does not display but you
must enter it.
7
It is the first application rate.
8
It is the second application rate. If there is only one application
rate, use the Rate 1 value again.
9
It displays the volume of material in the sprayer tank. Reset the
volume when you refill the tank.
0
It is a 24 hour clock or an elapsed timer. You reset it when you
turn off the console computer.
calibrate the system operation.
10
RATE 2
VOL
TIME
CAL
TANK
0
8
9
VOL /
AREA /
DATA
MIN
HOUR
MENU
Function*
2
)
SELF
TEST
ENTER
G013305