Kenmore 405.84086 Use & Care Manual page 12

Portable air conditioner
Hide thumbs Also See for 405.84086:
Table of Contents

Advertisement

Water drainage
1.
For dehumidifying mode, pull the drain
plug from the upper drain hole fitting.
Push the open end of the supplied drain
hose securely over the fitting. Place the
adaptor end of the hose directly over a
floor drain so that the water will flow into
the drain (See Fig.19).
You may also screw the end of a garden
hose over the threaded fitting of the upper
drain hole.
NOTE: Make sure the hose is securely fitted to
the upper drain so there are no leaks. Direct
the hose toward the floor drain so that there
are no kinks to stop or interfere with water
flow. Make sure that the end of the hose is
positioned so that water flows into the floor
drain.
2.
If water in the bottom tray reaches a
predetermined level, the unit beeps 8
times and P1 appears in the display.
Air conditioning or dehumidifying will
immediately stop; however, the fan
will continue to operate.
Carefully move the unit to a drain
location, and remove the bottom
drain plug to drain the water from
the bottom tray (See Fig.20).
NOTE: Be sure to reinstall the bottom drain plug
before using the unit.
Remove the
upper drain plug
12
Continuous
Drain Hose
drain hose
adaptor
Fig.19
Fig.20
Bottom Drain Plug