Hydraulic Valve Solenoid Functions - Toro 03550 Reelmaster 5500-D Operator's Manual

2 and 4 wheel drive traction units
Hide thumbs Also See for 03550 Reelmaster 5500-D:
Table of Contents

Advertisement

3. Connect the Diagnostic ACE display connector to the
harness connector. Make sure correct overlay decal is
positioned on Diagnostic ACE display.
4. Turn the key switch to the on position, but do not start
machine.
1
Figure 34
1. Diagnostic Ace
Note: The red text on the overlay decal refers to input
switches and the green text refers to outputs.
5. The inputs displayed LED, on lower right column of
the Diagnostic ACE, should be illuminated. If the
outputs displayed LED is illuminated, press the toggle
button, on Diagnostic ACE, to change the LED to
inputs displayed.
6. The Diagnostic ACE will illuminate the LED associated
with each of the inputs when that input switch is closed.
Individually, change each of the switches from open to
closed (i.e., sit on seat, engage traction pedal, etc.), and
note that the appropriate LED on Diagnostic ACE will
blink on and off when corresponding switch is closed.
Repeat on each switch that is it possible to be changed
by hand.
7. If switch is closed and appropriate LED does not turn
on, check all wiring and connections to switch and/or
check switches with an ohm meter. Replace any
defective switches and repair any defective wiring.
The Diagnostic ACE also has the ability to detect which
output solenoids or relays are turned on. This is a quick
way to determine if a machine malfunction is electrical or
hydraulic.
Verifying Output Function
1. Park machine on a level surface, lower the cutting units,
stop the engine and engage the parking brake.
2. Open control panel cover. Locate wire harness and
connectors near controller. Carefully unplug loopback
connector from harness connector.
3. Connect the Diagnostic ACE connector to the harness
connector. Make sure correct overlay decal is positioned
on Diagnostic ACE.
4. Turn the key switch to the on position, but do not start
machine.
Note: The red text on the overlay decal refers to input
switches and the green text refers to outputs.
5. The outputs displayed LED, on lower right column of
Diagnostic ACE, should be illuminated. If inputs
displayed LED is illuminated, press the toggle button,
on Diagnostic ACE, to change LED to outputs
displayed.
Note: It may be necessary to toggle between inputs
displayed and outputs displayed several times to do the
following step. To toggle back and forth, press toggle
button once. This may be done as often as required. Do not
hold the button.
6. Sit on the seat and attempt to operate the desired
function of the machine. (If you need help verifying the
correct input settings for each function, refer to the
Logic Chart on page 27) The appropriate output LED's
should illuminate to indicate that the ECU is turning on
that function.
Note: If any output LED is blinking, this indicates an
electrical problem with that output. Repair or replace
defective electrical parts immediately. To reset a blinking
LED, turn the key switch off, then back on.
If no output LED's are blinking, but the correct output
LED's do not illuminate, verify that the required input
switches are in the necessary positions to allow that
function to occur. Verify correct switch function.
If the output LED's are on as specified, but the machine
does not function properly, this indicates a non–electrical
problem. Repair as necessary.
Note: Due to electrical system constraints, the output
LED's for start, preheat and etr/alt may not blink even
though an electrical problem may exist for those functions.
If the machine problem appears to be with one of these
functions, be certain to check the electrical circuit with a
volt/ohm meter to verify that no electrical problem exists to
these functions.
If each output switch is in the correct position and
functioning correctly, but the output LED's are not
correctly illuminated, this indicates an ECU problem. If this
occurs, contact your Toro Distributor for assistance.
Important
The Diagnostic ACE display must not be
left connected to the machine except for trouble shooting. It
is not designed to withstand the environment of the
machine's every day use. When done using Diagnostic
29