Battery Care; Fuses - Toro Groundsmaster 4100-D 30411 Operator's Manual

Traction unit
Table of Contents

Advertisement

negative (-) terminal of the battery and secure them
with the bolts and nuts. Make sure that the positive
(+) terminal is all of the way onto the post and the
cable is positioned snug to the battery. The cable
must not contact the battery cover. Slide the rubber
boot over the positive terminal to prevent a possible
short from occurring.
Battery terminals or metal tools could short
against metal components causing sparks.
Sparks can cause the battery gasses to explode,
resulting in personal injury.
• When removing or installing the battery, do
not allow the battery terminals to touch any
metal parts of the machine.
• Do not allow metal tools to short between
the battery terminals and metal parts of the
machine.
Incorrect battery cable routing could damage
the machine and cables causing sparks. Sparks
can cause the battery gasses to explode,
resulting in personal injury.
disconnect
• Always
battery cable before disconnecting the
positive (red) cable.
• Always
connect
cable before connecting the negative (black)
cable.
8. Coat both battery connections with Grafo 112X
(skin-over) grease, Toro Part No. 505-47, petroleum
jelly, or light grease to prevent corrosion. Slide the
rubber boot over the positive terminal.
9. Install the battery cover.

Battery Care

Battery type is group 24.
Important: Before welding on the machine,
disconnect the negative cable from the battery to
prevent damage to the electrical system.
Note: Check the battery condition weekly or after every
50 hours of operation. Keep the terminals and the entire
battery case clean because a dirty battery will discharge
slowly. To clean the battery, wash the entire case with
the negative (black)
the positive (red) battery
a solution of baking soda and water. Rinse with clear
water. Coat the battery posts and cable connectors with
Grafo 112X (skin-over) grease (Toro Part No. 505-47)
or petroleum jelly to prevent corrosion.

Fuses

There are 5 fuses in the electrical system. They are
located below the operators control panel (Figure 54
and Figure 55).
1. Fuses
1. Power outlet
2. Seat switch
3. Ignition switch
42
Figure 54
Figure 55
4. Power Take Off (PTO)
5. Starter solenoid
6. Light kit