3. INSTALLATION

3.1 INSTALLATION REQUIREMENTS

3.1.1 ENVIRONMENT

1. Temperature Range: 10°C to 32°C (50°F to 89.6°F)
2. Humidity Range: 15% to 80% RH
3. Ambient Illumination: Less than 1,500 lux (do not expose to direct sunlight.)
4. Ventilation: Room air should turn over at least 3 times/hr/person
5. Ambient Dust: Less than 0.10 mg /m
6. Avoid areas which are exposed to sudden temperature changes. This includes:
1) Areas directly exposed to cool air from an air conditioner.
2) Areas directly exposed to heat from a heater.
7. Do not place the machine in an area where it will be exposed to corrosive
gases.
8. Do not install the machine at any location over 2,000 m (6,500 ft.) above sea
level.
9. Place the machine on a strong and level base. (Inclination on any side should
be no more 5 mm.)
10. Do not place the machine where it may be subjected to strong vibrations.

3.1.2 POWER REQUIREMENTS


CAUTION
1. Make sure that the wall outlet is near the machine and easily accessible.
2. Make sure the plug is firmly inserted in the outlet.
3. Avoid multi-wiring.
4. Be sure to ground the machine.
1. Input voltage level: Stinger - P3
2. Permissible voltage fluctuation : 5%
3. Do not set anything on the power cord.
SM
3
(2.7 x 10
120 V, 60 Hz: More than 8.0 A (for North America)
220 V ~ 240 V, 50/60 Hz: More than 8.0 A (for Europe)
Stinger - P4
120 V, 60 Hz: More than 6.0 A (for North America)
220 V ~ 240 V, 50/60 Hz: More than 5.0 A (for Europe)
3-1
INSTALLATION REQUIREMENTS
-6
3
oz/yd
)
G031/G032