3. ADJUSTMENTS AND CHECKS
3.5.2
EXT Data Setting menu
The [EXT Data Setting] menu sets up the external equipment connected to this sonar.
Date&Time: Select the input format for date and time data. (NONE, CIF, NMEA)
Heading: Select the input format for heading data. (NONE, AD10, CIF, NMEA)
Speed&Course: Select the input format for ship's speed and course data. (NONE,
CIF, NMEA)
Speed Sensor: Select the input format for speed data. (NONE, GPS/DR, DOPPLER/
DR) If response is slow, select GPS.
Lat/Lon: Select the input format for position data. (NONE, CIF, NMEA)
POS Sensor: Select the type of the navigator used. Select [Auto Sel] when more than
one navigator is connected. The priority for auto selection is GPS/DR> Loran-C. (Lo-
ran C, GPS/DR, Auto Sel)
Water Depth: Select the input format for water depth. (NONE, CIF, NMEA)
Water Temp: Select the input format for water temperature. (NONE, CIF, NMEA)
Water Current: Select the input format for water current. (NONE, CIF, NMEA)
Wind: Select the input format for wind data. (NONE, CIF, NMEA)
Net Depth: Select the input format for net depth data. (NONE, CIF)
CIF Type: Select the CIF type to use. (CIF-2000, CS-120A)
3.5.3
Test&Initialization menu
The [Test&Initialization] menu provides diagnostic tests and the means to restore de-
fault settings. This menu is not used in the installation of this sonar.
3.5.4
Others menu
Trackball Speed: Select the tracking speed for the trackball. (Slow, Normal, Fast)
Hull Unit Stroke: Select the stroke of the hull unit. (1200 mm, 1600 mm)
T_parameter: Debugging facility. For the serviceman.
Error Code List: Confirm error codes.
Explorer: Confirm and search files.