Panasonic VDR-M70EG Service Manual page 123

Table of Contents

Advertisement

7) Connect the oscilloscope CH1 to "EVF-B (pin 6)" of
Skylark Connection jig.
8) Use the same procedure as in step 3) to equalize levels a
and b of the waveform.
9) After step 8) is complete, be sure to click the NEXT
button, and then proceed with the SUB BRIGHT BLUE
ADJUSTMENT screen.
10) Use the same procedure as in step 3) to equalize levels c
and d of the waveform.
11) After step 10) is complete, be sure to click the SAVE
button and then proceed with the BL DET screen.
Note that clicking the RETURN button will restore the
EVF ADJUSTMENT MENU screen to the status before
the adjustment was performed.
12) Click either button on the BL DET screen according to
the voltage checked in "(1) EVF BL DET Check": "High"
button when the check value is 5 V, or "Low" button
when it is 0 V.
13) When BL DET is complete, the ADJUSTMENT
FINISHED dialog will appear: Click the OK button in
dialog to restore the EVF ADJUSTMENT MENU screen.
14) Click the RETURN button in EVF ADJUSTMENT
MENU to restore the ADJUST MENU screen.
Fig. 6-4-16 Waveform of White Balance Adjustment
Downloaded From CamcorderManual.com Panasonic Manuals
c
a
d
b
VDR-M70EG / VDR-M70EB / VDR-M70GC / VDR-M50EG / VDR-M50EB / VDR-M50GC
SUB CONTRAST BLUE ADJUSTMENT
screen.
MANUAL ADJUSTMENT PROGRAM for SERVICE STATION
SUB CONTRAST BLUE ADJUSTMENT
UP
9
SAVE
CONNECTION
SUB BRIGHT BLUE ADJUSTMENT
screen.
MANUAL ADJUSTMENT PROGRAM for SERVICE STATION
SUB BRIGHT BLUE ADJUSTMENT
UP
11
NEXT
CONNECTION
BL DET screen.
MANUAL ADJUSTMENT PROGRAM for SERVICE STATION
BL DET
High
CONNECTION
ADJUSTMENT FINISHED dialog
FINISHED
ADJUSTMENT FINISHED.
OK
123
DOWN
8
RETURN
DOWN
10
RETURN
Low
12
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vdr-m70ebVdr-m70gcVdr-m50egVdr-m50ebVdr-m50gc