4.8.7 Dot-Position Adjustment (Dot-printing model)

NOTE
NOTE
4 - 18
It is recommended to adjust the position of dots at least once a year.
Adjusting procedure
(1) Turn the recorder power on and allow a warm-up time of more than 30 minutes.
(2) Check that the environmental conditions are within normal operating ranges (see
subsection 4.8.6).
(3) To enter the SET UP mode, turn the power switch off, and turn on again while
pressing the [CH UP] (
(4) Select [
] by pressing the [
(5) Select [
] (leftward movement) or [
[
] (movement toward the center of dotted line) by pressing the [
and press the [ENT] key.
Selection and adjustment should be made in the order of HYS NULL FULL.
(6) First, the HYS should be adjusted. A zigzag line will be drawn in the center area
of the chart. When the line is as Figure a, increase the set value, but in case of
Figure b, decrease it.
Figure a
The setting consists of a number of five digits.
Select the digit by pressing the [ ] key, and select a numeral by the [
setting range is –7 to 7. Finally press the [ENT] key after all codes are entered.
The dot position movement corresponding to [1] is 0.1 mm.
If the [ENT] key is pressed while setting the numeric codes, the indication
changes to [
], and the numeric codes already set stay valid.
However, pressing the [ESC] key turns them invalid.
(7) The indicator displays [
position.
Confirm the dot carriage position and press the [ENT] key.
(8) The indication returns to [
illegal, press the [ENT] key and repeat step (6); if correct, press the [
select [
] or [
(9) Next, the NULL and FULL should be adjusted. Increase or decrease the setpoint
value to make the dot position accurately overlap the graduated line of the chart.
The setting consists of is a number of five digits.
The setting range is 1 to 15 for NULL, and 970 to 1030 for FULL. Finally press
the [ENT] key after all codes are entered.
The dot position movement corresponding to [1] is 0.1 mm. Decreasing the
numeral moves the dot position leftward, and increasing moves it rightward.
ENT) key.
] key, and press the [ENT] key.
] (rightward movement) or
Figure b
], and the dot carriage will move to the adjusted
] and recording stops. If the recording position is
].
] key,
The arrows show the moving
direction of the printer head.
] key; the
] key and

Advertisement

Table of Contents
loading

Table of Contents