4.2 Programming Flowchart (continued)
Continued From Previous Page
TOT AL DECIMAL
GAL
LIT
TOT AL
FT3
DESCRIPT OR
M3
"blank"
(BBL, MCF)
SEC
SCALE
NNIN
(ratemeter)
HRS
(Days)
RA TE
DECIMAL
LOCA TION
NORMALIZATION
NORMALIZATION
NORMALIZA
DELA Y
0.1 to 99.9
to 99.9
to
OUT LOW
(4mA)
OUT HIGH
(20mA)
D 1
D 1
D 1
PULSE
D 10
D 10
D 10
SCALER
D100
D100
D100
(divider)
oFF
oFF
oFF
.5
PULSE
.25
WIDTH
.125
(seconds)
.0625
LOCK
CODE
yes
TURN LOCK
ON or OFF
no
TDEC
Press the
E
Press the E key to enter the displayed decimal location.
12345678
Press the M key to skip and keep the existing location
M
Press the
Press the E key to enter the displayed descriptor.
E
Press the M key to skip and keep the existing descriptor.
ToT DESC
NOTE: When option "D" (rate per day) is ordered; selections are:
M
Press the
SEC
Press the E key to enter the displayed scale setting.
E
Press the M key to skip and keep the existing setting.
r SCALE
NOTE: When option "D" (rate per day) is ordered; selections are:
M
1234
Press the
Press the E key to enter the displayed decimal location.
E
R DECLoC
Press the M key to skip and keep the existing location
M
1
Press the
E
Press the E key to enter the displayed value.
nor
Press the M key to skip and keep the existing value.
M
0.1
Press the
Press the
E
delay
Press the E key to enter the displayed value.
Press the M key to skip and keep the existing value.
M
Press the
0000
value). This will only display on units with Analog Output.
value). This will only display on units with Analog Output.
E
Press the
oUT Lo
Press the E key to enter the displayed value.
M
Press the M key to skip and keep the existing value.
99999
Press the
value). This will only display on units with Analog Output.
value). This will only display on units with Analog Output.
E
oUT HI
Press the
Press the E key to enter the displayed value.
M
Press the M key to skip and keep the existing value.
D 1
Press the
E
output.
Pul scale
Press the E key to enter the displayed pulse scale divider.
Press the M key to skip and keep the existing pulse scale value.
M
.5 .5
Press the
Press the E key to enter the displayed pulse width.
E
p uuidth
Press the M key to skip and keep the existing pulse width.
This will not display if Pulse Out is turned OFF.
M
0000
Press the
Press the
E
loc code
Press the E key to enter the displayed value.
Press the M key to skip and keep the existing value.
M
yes
Press the
Press the E key to enter the displayed lock setting.
E
loC UnIt
Press the M key to skip and keep the existing setting.
M
RUN MODE
key to step the totalizer decimal to the desired location.
key to step to the desired totalizer descriptor.
GAL, BBL, MCF, M3, "blank"
key to step to the desired scale setting.
min, sec, days
key to step the ratemeter decimal to the desired location.
key to increment each individual digit of the "nor" factor.
key to increment each individual digit of the delay.
key to increment each individual digit of the delay.
key to advance to the next digit.
key to increment each individual digit of the out low setting (4mA
key to advance to the next digit.
key to increment each individual digit of the out high setting (20mA
key to advance to the next digit.
key to step to the desired pulse scale divider for the pulse
key to step to the desired pulse width for the pulse output.
key to increment each individual digit of the lock code.
key to increment each individual digit of the lock code.
key to advance to the next digit.
key to step to the desired lock setting.
9