Install, operate and service Martin™ products only as directed in their user manuals, or
you may create a safety hazard or cause damage that is not covered by product
warranties.
Follow the safety precautions listed below and observe all warnings in this manual and
printed on the product. Keep this manual for future use.

Protection from electric shock

Do not expose the fixture to rain or moisture.
Disconnect the fixture from AC power before carrying out any installation or
maintenance work, such as changing the lamp, and when the fixture is not in use.
Ensure that the fixture is electrically connected to ground (earth).
Use only a source of AC power that complies with local building and electrical codes and
has both overload and ground-fault (earth-fault) protection.
Socket outlets or external power switches used to supply the fixture with power must be
located near the fixture and easily accessible so that the fixture can easily be
disconnected from power.
The power input cable must be rated 10 A, hard usage type, heat-resistant to 90° C
(194° F) minimum and temperature-rated to suit the application. It must have three
conductors and an outer cable diameter of 5 - 15 mm (0.2 - 0.6 in.). In the USA and
Canada the cable must be UL listed, type SJT or equivalent. In the EU the cable must
be type H05VV-F or equivalent.
Use only a Neutrik PowerCon TRUE1 cable connector to connect to the fixture's power
socket.
Before using the fixture, check that all power distribution equipment and cables are in
perfect condition and rated for the current requirements of all connected devices.
Isolate the fixture from power immediately if the power plug or any seal, cover, cable, or
other component is damaged, defective, deformed, wet or showing signs of overheating.
Do not reapply power until repairs have been completed.
Replace defective fuses with ones of the specified type and rating only.

Protection from burns and fire

Do not use the fixture to illuminate surfaces within 15 m (49.2 ft.) of the fixture.
Do not operate the fixture if the ambient temperature (T
) exceeds 40° C (104° F).
a
The surface of the product casing can reach up to 90° C (194° F) during operation.
Avoid contact by persons and materials. Allow the fixture to cool for at least 20 minutes
before handling.
Keep flammable materials well away from the fixture. Keep all combustible materials
(e.g. fabric, wood, paper) at least 100 mm (4 in.) away from the fixture head.
Ensure that there is free and unobstructed airflow around the fixture. Provide a minimum
clearance of 100 mm (4 in.) around fans and air vents.
Do not attempt to bypass thermostatic switches or fuses.
Do not stick filters, masks or other materials onto any optical component.