1.3 Specifications

1.3.1 General Description

Control Bus
Communication Bus
Switching
Power Input
Power Consumption
(when fully mounted)
Maximum Power Failure Tolerance
Memory Backup Duration
Dialling
Mode Conversion
Ring Frequency
Trunk Loop Limit
Operating
Environment
Conference Call Trunk
Music on Hold (MOH)
Paging
Serial Interface Port
RJ45 Port
Original bus (16-bit, 8 MHz, 10 megabytes per second)
H.100 bus conformity (1024 time slots)
Non-blocking
KX-NCP500
100 V AC to 130 V AC; 1.0 A/200 V AC to 240 V AC; 0.6 A; 50
Hz/60 Hz
KX-NCP1000
100 V AC to 130 V AC; 1.3 A/200 V AC to 240 V AC; 0.8 A; 50
Hz/60 Hz
KX-NCP500
51 W
(240 V: 122 VA, 200 V: 113 VA, 130 V: 100 VA, 100 V: 92 VA)
KX-NCP1000
65 W
(240 V: 142 VA, 200 V: 134 VA, 130 V: 119 VA, 100 V: 113 VA)
300 ms
*1
7 years
Trunk
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Extension
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
DP-DTMF, DTMF-DP
20 Hz/25 Hz (selectable)
1600 W maximum
Temperature
0 °C to 40 °C
Humidity
10 % to 90 % (non-condensing)
From 10 ´ 3-party conference call to 4 ´ 8-party conference call
1 port (Level Control: -6 dB to +6 dB per 3 dB)
MOH1: Selectable Internal/External Music Source port
Internal
Level Control: -6 dB to +3 dB per 3 dB
External
1 port (Volume Control: -15 dB to +6 dB per 3 dB)
RS-232C
1 (maximum 115.2 kbps)
MNT Port
1 (for PC connection)
LAN Port
1 (for LAN connection)