Gsm Rx Chain Activation For Manual Measurements / Gsm Rssi Measurement; Transmitter Troubleshooting; General Instructions For Tx Troubleshooting - Nokia N72 Service Manual

Hide thumbs Also See for N72:
Table of Contents

Advertisement

Nokia Customer Care
For service tool usage instructions, refer to section Service Tools and Service Concepts.

GSM Rx chain activation for manual measurements / GSM RSSI measurement

Context
RSSI signal measurement is the main Rx troubleshooting measurement. The test measures the strength of
the received signal.
I and Q branches can be measured separately. In GSM, the input signal can be either real GSM signal or a CW
(Continuous Wave) signal that is 67.771 kHz above the carrier frequency.
Steps
Phoenix service software.
1. Start
2. Choose Testing→GSM→RSSI Reading .
3. Set the RF signal generator for channel frequency +67.771 kHz CW mode with –80 dBm signal.
Alternatively set the cellular tester downlink channel to the appropriate channel. Make sure that the tester
is set to continuous mode, not to burst mode.
RSSI Reading window, select the appropriate band and channel.
4. In the
5. To start the measurement, activate GSM Rx chain, click Start.
Results
RSSI reading values of the selected band and channel are displayed. The RSSI level must be the same value
which is set at the signal generator (-80 dBm).

Transmitter troubleshooting

General instructions for Tx troubleshooting

Context
• Tx troubleshooting requires Tx operation.
• Do not transmit on frequencies that are in use.
• Transmitter can be controlled in the local mode for diagnostic purposes.
Page 7 –10
RSSI Reading window
Figure 61
COMPANY CONFIDENTIAL
Copyright © 2006 Nokia. All rights reserved.
RF Troubleshooting and Tuning Guide