Removal Procedure
Steps
10. Remove solenoid coil
Remove the screw on the solenoid coil,
and then remove the solenoid coil.
11. Remove compressor
1
Unsolder the pipes (including the soldering
joint
among
compressor, the condenser, the gas valve
and the liquid valve) connected to the
compressor
unsoldering the joints, discharge the
refrigerant completely
Remove the 3 foot nuts fixing the
2
compressor with wrench, and then remove
the compressor.
the
4-way
valve,
the
at
first.
(NOTE:
Before
Procedure
solenoid coil
screw
4-way valve assy
compressor
gas valve
liquid valve
nut
63