How To Check Simply The Main Part - Gree GWH18PD-K3NNA1A Service Manual

Table of Contents

Advertisement

9.4 How to Check Simply the Main Part

(1) Malfunction of temperature sensor
40
Start
Is the wiring
terminal between temperature
sensor and the controller loosened or
poor ly contacted?
no
Is there short circuit due to trip over
of the par ts?
no
Is the temperature
sensor normal according to the
Resistance Table?
yes
Replace the controller with
one of the same model
End
yes
Insert the temperature
sensor tightly
M alfunction is
no
eliminated.
yes
Make the parts upright
Malfunction is
no
eliminated.
no
Replace it with a
temperature sensor
of the same model
Malfunction is
no
removed.
yes
Troubleshooting
yes
yes

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gwh24pd-k3nna1a

Table of Contents