Banner DF-G3 Quick Start Manual

Long range expert dual display fiber amplifier with analog output
Hide thumbs Also See for DF-G3:

Advertisement

DF-G3 Long Range Expert
Fiber Amplifier with Analog Output

Quick Start Guide

Advanced sensor with dual digital displays for use with plastic and glass fiber optic assemblies; analog current or voltage
output models with an independent NPN or PNP discrete output are available.
This guide is designed to help you set up and install the DF-G3 Long Range Expert Dual Display Fiber Amplifier with Analog
Output. For complete information on programming, performance, troubleshooting, dimensions, and accessories, please
refer to the Instruction Manual at http://www.bannerengineering.com. Search for p/n 190341 to view the Instruction
Manual. Use of this document assumes familiarity with pertinent industry standards and practices.
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to
serious injury or death. This device does not include the self-checking redundant circuitry necessary
to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an
energized or de-energized sensor output condition.
Overview
Figure 1. DF-G3 Dual Output Analog with Discrete Output
Original Document
190340 Rev. B
Dual Display
1
Analog and Discrete Output LEDs
2
CH1/CH2 Switch
3
RUN/PRG/ADJ Mode Switch
4
Lever Action Fiber Clamp
5
Red Signal Level
Green CH1 Analog Output Signal or CH2
6
Threshold
7
+/SET/- Rocker Button
3 March 2016
190340

Advertisement

Table of Contents
loading

Summary of Contents for Banner DF-G3

  • Page 1: Quick Start Guide

    NPN or PNP discrete output are available. This guide is designed to help you set up and install the DF-G3 Long Range Expert Dual Display Fiber Amplifier with Analog Output. For complete information on programming, performance, troubleshooting, dimensions, and accessories, please refer to the Instruction Manual at http://www.bannerengineering.com.
  • Page 2: Installation Instructions

    For 9 m (29.5 ft) cable, change the suffix 2M to 9M in the 2 m model number (DF-G3-NS-9M) • For 150 mm (6 in) PVC cable with a M8/Pico-style QD model, change the suffix 2M to Q3 in the 2 m model number (DF-G3-NS-Q3) •...
  • Page 3: Installing The Fibers

    Dual Display Fiber Amplifier with Analog Output Remove from a DIN rail 1. Push the DF-G3 up on the DIN rail (1). 2. Pivot the DF-G3 away from the DIN rail and remove it (2). Installing the Fibers Follow these steps to install glass or plastic fibers.
  • Page 4: Wiring Diagrams

    ™ DF-G3 Long Range Expert Dual Display Fiber Amplifier with Analog Output Wiring Diagrams NPN Models PNP Models 1 = Brown 2 = White 10-30V dc (Current Models) 10-30V dc (Current Models) 3 = Blue 12-30V dc (Voltage Models) 12-30V dc (Voltage Models) 4 = Black –...
  • Page 5: Remote Input

    ™ DF-G3 Long Range Expert Dual Display Fiber Amplifier with Analog Output Dual Output LEDs The output LEDs provide a visible indication of when the associated output is active. • 1 represents the Channel 1 analog output. When on, it indicates that the signal is within the analog range.
  • Page 6: Program Mode

    DF-G3 Long Range Expert Dual Display Fiber Amplifier with Analog Output Program Mode Channel 1 Analog Menu Program (PRG) mode allows the following settings to be programmed in the DF-G3. CH1 Analog Factory Default Settings: tch SEL1 2-pt tch rESP SPd...
  • Page 7: Adjust Mode

    Dual Display Fiber Amplifier with Analog Output Channel 2 Discrete Menu Program (PRG) mode allows the following settings to be programmed in the DF-G3. When CH2 is selected in Program mode, the settings below can be configured for CH2 discrete output and are independent from CH1 settings.
  • Page 8 ™ DF-G3 Long Range Expert Dual Display Fiber Amplifier with Analog Output CH1 Analog Output Two-Point TEACH • Establishes defined endpoints for the analog output range • Analog endpoints can be adjusted by using the "+" and "-" rocker button (Manual Adjust) Two-Point TEACH is used when two conditions can be presented statically to the sensor.
  • Page 9 ™ DF-G3 Long Range Expert Dual Display Fiber Amplifier with Analog Output Darkest Taught Lightest Taught Condition Condition Sensor positions threshold midway between taught conditions Output OFF Output ON Darkest Position Most Light (no signal) adjusted by (saturated Manual Adjust signal) Figure 4.
  • Page 10 ™ DF-G3 Long Range Expert Dual Display Fiber Amplifier with Analog Output Sensing window center adjusted by Manual Adjust Sensor positions window thresholds a programmable % offset from the presented condition Output OFF Output ON Output OFF Darkest Condition Most Light...
  • Page 11: Specifications

    Figure 9. Calibration SET (Light Operate shown) Specifications Sensing Beam DF-G3: Visible red, 635 nm DF-G3IR: Infrared, 850 nm DF-G3LIR: Long infrared, 1450 nm Supply Voltage Voltage output models: 12 V to 30 V dc Class 2 (10% maximum ripple)
  • Page 12 ™ DF-G3 Long Range Expert Dual Display Fiber Amplifier with Analog Output Analog Output Rating Voltage Outputs: 2.5 kOhm minimum load resistance Current Outputs: 1 kOhm maximum load resistance at 24 V; maximum load resistance = [(Vcc - 4)/.02] Ohms...
  • Page 13 Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period.