To confi gure thresholds
on the iGate
Connect
thermostat:
From the Home screen,
press MENU.
Select
Settings
Installation.
Select Thresholds.
18
HW Pump Confi g (If Applicable)
Water Heating Delta T Sets the potable
water fl ow rate for the water heating mode.
The variable speed potable water pump will
adjust the potable water fl ow to maintain the
selected temperature diff erence between the
entering and leaving potable water during
the water heating mode. Valid range: 8.0°F to
12.0°F.

Thresholds

This section confi gures the temperature, time,
and capacity thresholds associated with the
heating, cooling, and hot water (if applicable)
equipment. You must confi gure the Equipment
settings before setting the thresholds. Only the
applicable threshold settings will be displayed.
Allow Auto Heat/Cool
Allows the user to be able to operate the unit in
the auto changeover heat/cool mode. Select Yes
for the user to be able to operate the thermostat
in the auto heat/cool mode, otherwise select No.
Heat/Cool Min Delta
Selects the minimum temperature diff erence
between the heating and cooling set points
when the thermostat is operated in the auto
changeover heat/cool mode. Valid range: 2°F to
10°F. The default value is 5°F.
Advanced Settings
Allows the installer to select the controller to
confi gure, typically an EXM.