To confi gure the iGate

Connect thermostat:

From the Home screen,
press MENU.
Select
Settings
Installation.
Select
Thermostat Confi
To confi gure equipment
on the iGate
Connect
thermostat:
From the Home screen,
press MENU.
Select
Settings
Installation.
Select Equipment.
14
CONFIGURING THE IGATE
CONNECT THERMOSTAT
The fi rst step after installing the iGate
thermostat is to confi gure the settings for the
equipment being connected.
An access code is required to enter the
Installation Settings menu. The access code is
4795.

Thermostat Confi g

Aux Heat Option
Confi gures the thermostat for electric auxiliary
g.
heat or no auxiliary heat (none).

Equipment

Capacity Confi guration
Min Heating Capacity Confi gures the
minimum unit heating capacity. When the
space requires a heating capacity below this
setting the unit will cycle off . Range will
depend on unit model.
Max Heating Capacity Confi gures the
maximum unit heating capacity. When the
space requires a heating capacity above this
setting the unit will call for auxiliary heat (if
applicable). Range will depend on unit model.
Min Heating Airfl ow Confi gures the unit
airfl ow while operating at minimum capacity
in the heating mode. The installer may wish
to select a higher cfm than the nominal cfm
for this setting to ensure proper air movement