Troubleshooting

Malfunction
No power at the sensor
Lights do not switch ON
Lights do not switch OFF
Lights keep switching
ON/OFF
Lights switch ON without
obvious movement
www.steinel.net
(800) 852-4343
Cause
breaker has tripped;
light switch is in OFF
position
short circuit
light level setting is in
nighttime mode during
daytime operation
lamp burned out
power is OFF
breaker has tripped
detection zone not
correctly adjusted
abundant heat from
the fi xture is within
detection zone and
keeps lights ON as a
result of temperature
change
switched ON light is
within detection zone
animals moving in
detection zone
wind is moving trees
and bushes in the
detection zone
cars in the street are
detected
sudden temp changes
due to weather (wind,
rain, snow) or exhaust
air from fans or open
windows
Remedy
reset breaker, turn
light switch to ON
position, check wiring
with voltage tester
check for proper
wiring connections
adjust light level
setting
replace lamp
turn power ON at
circuit breaker
reset breaker
readjust
readjust zone or apply
shroud
adjust detection zone
or apply shrouds,
increase distance
adjust zone or apply
shrouds
adjust zone or apply
shrouds
adjust zone or apply
shrouds adjust
adjust detection zone
or install in a different
place