Make Electrical Power Supply Connection To Downdraft Vent - KitchenAid KIRD862VSS Installation Instructions And Use & Care Manual

30" (76.2 cm) and 36" (91.4 cm) retractable (pop-up) downdraft vent system
Table of Contents

Advertisement

Available languages

Available languages

7. Use UL listed wire connectors and connect the gray wires
(G) together.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
8. Connect the green (or yellow/green) ground wire to the
green/yellow ground wire (H) in the terminal box using UL
listed wire connectors.
9. Reinstall the in-line blower terminal box cover and screw.
10. Reinstall the front cover of the in-line blower housing and
secure it with 10 mounting screws.
Electrical Connection Inside Downdraft Vent Between
In-Line Blower System and Downdraft Vent
NOTE: Discard the 6-wire connector assembly supplied with
the in-line blower motor system.
1. With the downdraft vent mounted, locate the bottom wiring
cable (5 wires) inside the downdraft vent terminal box.
2. Connect the wires from the bottom wiring cable (5 wires)
inside the downdraft vent terminal box to the wires from
the in-line blower wiring conduit inside the downdraft vent
terminal box.
3. Connect the same color wires to each other (black to black,
white to white, etc.) using UL listed wire connectors.
NOTE: Connect the green (or green/yellow) ground wire from
the wiring conduit to the green (or bare) ground wire from the
home power supply using UL listed wire connectors.
(See the "Make Electrical Power Supply Connections to
Downdraft Vent" section.)
A
A. UL listed or CSA approved
1
/
" (1.3 cm) wiring conduit
2
B. UL listed wire connectors
C. Black wires
D. White wires
E. Red wires
4. Go to "Make Electrical Power Supply Connection
to Downdraft Vent" section.
22
B
C
D
E
F
G
H
I
F. Blue wires
G. Gray wires
H. Green (or green/yellow)
wire
I. Bottom wiring cable
(5 wires)
Make Electrical Power Supply Connection
to Downdraft Vent
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Locate the downdraft vent terminal box.
A
A. Terminal box
B
E
A. Green or green and yellow
ground wires
B. White wires
C. UL listed wire connectors
3. Use UL listed wire connectors and connect black wires
(D) together.
F
C
D
A
D. Black wires
E. UL listed or CSA approved
conduit connector
F. Downdraft vent wiring