Complete Installation - KitchenAid KIRD862VSS Installation Instructions And Use & Care Manual

30" (76.2 cm) and 36" (91.4 cm) retractable (pop-up) downdraft vent system
Table of Contents

Advertisement

Available languages

Available languages

Complete Installation

(Interior-Mounted Motor)
NOTE: The downdraft vent system is supplied with a 3
(8.3 cm x 25.4 cm) back draft damper and a 6" (15.2 cm) round
vent transition with damper. Refer to "3
25.4 cm) Back Draft Damper" or "6" (15.2 cm) Round Vent
Transition with Damper," depending upon the type of venting
you are using.
3
/
" x 10" (8.3 cm x 25.4 cm) Back-Draft Damper
1
4
1. Attach the 3¼" x 10" (8.3 cm x 25.4 cm) back draft damper
to the vent opening in the blower motor box, using three
3.5 x 9.5 mm screws.
B
A. 3.5 x 9.5 mm screws
B. 3¼" x 10" (8.3 cm x 25.4 cm) back-draft damper
6" (15.2 cm) Round Vent Transition with Damper
1. Attach the 6" (15.2 cm) round vent transition to vent opening
(left- or right- side venting only is recommended), using two
3.5 x 9.5 mm screws.
A
A. 3.5 x 9.5 mm screws
B. 6" (15.2 cm) round vent transition with damper
14
/
" x 10"
1
4
/
" x 10" (8.3 cm x
1
4
A
A
B
2. Remove 4 screws attaching the terminal box cover.
A
A. Terminal box cover
3. Determine which direction (front or rear) the home power
supply cable will enter the terminal box. Remove the
appropriate knockout from the front or rear panel and install a
/
" (12.7 mm) UL listed or CSA approved conduit connector.
1
2
4. Using 2 or more people, insert the downdraft vent into the
countertop cutout. Position downdraft vent so it is centered
in the cutout with the rear flange over the edge of the cutout
and the rear of the vent box against the edge of the cutout.
G
A. Rear flange of downdraft vent
B. Edge of cutout in countertop
C. Rear of downdraft vent
D. Cabinet back
A
B
C
D
E
F
E. Lower support leg
F. Cabinet floor
G. Countertop

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kxd4636yssKxd4630yss

Table of Contents