Troubleshooting - Hilti DX 351 BT Operating Instructions Manual

Hide thumbs Also See for DX 351 BT:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 20

9. Troubleshooting

Fault
Cartridge not transported
en
Cartridge strip cannot be removed
Cartridge doesn't fire
Cartridge strip melts
Cartridge falls out of the
cartridge strip
24
Printed: 20.08.2013 | Doc-Nr: PUB / 5069824 / 000 / 02
Possible cause
Damaged cartridge strip
Carbon build-up
Tool damaged
Tool overheated because of high
setting rate
Tool damaged
-WARNING-
Never attempt to pry a cartridge
from the magazine strip or tool.
Bad cartridge
Carbon build-up
-WARNING-
Never attempt to pry a cartridge
from the magazine strip or tool.
Tool is compressed too long
while fastening.
Fastening frequency is too high
Fastening frequency is too high
-WARNING-
Never attempt to pry a cartridge
from the magazine strip or tool.
Remedy
Clean the cartridge strip guide-
way (see 24)
If the problem persists:
Contact Hilti Repair Centre
Let the tool cool down and then
carefully try to remove the
cartridge strip (If the problem
persists: Contact Hilti Repair
Center)
Contact Hilti Repair Center
Manually advance the cartridge
strip one cartridge
If the problem occurs more often:
Clean the tool
(If the problem persists: Contact
Hilti Repair Center)
Compress the tool only briefly
while fastening.
Remove the cartridge strip
Disassemble the tool for fast
cooling and to avoid possible
damage
(If the tool cannot be disassem-
bled: Contact Hilti Repair Center)
Immediately discontinue using
the tool
Remove cartridge strip
Let the tool cool down
Clean the tool and remove loose
cartridge.
(If it is impossible to disassemble
the tool: Contact Hilti Repair
Center)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dx 351 btg

Table of Contents