Table 9-1. Astro Digital Spectra Power-Up Error Codes - Motorola ASTRO SPECTRA Service Manual

Hide thumbs Also See for ASTRO SPECTRA:
Table of Contents

Advertisement

9-2
9.3.1
ASTRO Digital Spectra
Error Code
01/02
01/81
01/82
01/84
01/88
01/90
01/92
02/10
02/81
02/82
02/84
02/88
02/90
02/A0
05/10
05/81
08/10
09/10
February 3, 2003

Table 9-1. ASTRO Digital Spectra Power-Up Error Codes

Description
External EEPROM checksum
non-fatal error
ROM checksum failure
External EEPROM checksum
failure
EEPROM is blank
RAM failure - Note: not a
checksum failure
General hardware failure
Internal EEPROM checksum
failure
DSP support IC checksum non-
fatal error
DSP ROM checksum failure
DSP RAM 1 failure
DSP RAM 2 failure
DSP RAM failure - Note: not a
checksum failure
General DSP hardware failure
(DSP startup message not
received correctly)
ADSIC checksum failure
Control head not communicating
with radio
Control head ROM checksum
failure
Siren/PA not communicating with
radio
Secure option not
communicating with radio
Basic Troubleshooting: Power-Up Error Codes
Corrective Action
Reprogram the codeplug.
Reprogram the FLASH memory.
Reprogram the codeplug.
Program the EEPROM.
Turn the radio off, then on.
Turn the radio off, then on.
Reprogram the codeplug.
Turn the radio off, then on.
Reprogram the FLASH memory.
Replace the VOCON board.
Replace the VOCON board.
Turn the radio off, then on.
Turn the radio off, then on.
Replace the VOCON board.
Turn the radio off, then on.
Replace the control head.
Turn the radio off, then on.
Turn the radio off, then on.