Figure 7. Wall and Ceiling Positions of Bracket
F. Punch out the selected wiring knockouts in the bracket (see
Figure 8).
Figure 8. Bracket Base as Viewed from the Rear
G. Press the bracket against the mounting surface and mark the
points for drilling. Drill out the holes and insert plastic anchors.
H. Route the cable through the bracket and into the detector as
shown in Figure 9.
I. Attach the bracket to the mounting surface using the two
screws supplied.
Figure 9. Routing the Cable
J. Tilt down or swivel the detector to face the desired direction.
Figure 10 shows the tilt/swivel possibilities.
Figure 10. Tilt/Swivel Limits
3.4 Using the Pet Alley Mask
If the presence of pets is expected within the protected site,
proceed as follows:
A. Separate the lens retainer from the front cover, as shown in
Figure 11.
B. Push the prefabricated plastic mask into place within the lens
retainer, as shown in Figure 12.
C. Remount the lens retainer within the front cover.
DE1260 DISCOVERY QUAD Installation Instructions
Figure 11. Releasing the Lens Retainer
Figure 12. Inserting the Mask into Place
3.5 Wiring
The terminal block wiring shown in Figure 13 is self explanatory.
Note: The E.O.L. terminal is simply a connection point for an
E.O.L. resistor, if the circuit requires one.
Figure 13. Terminal Block Wiring
3.6 Setting the Motion Event Counter
The location of the motion event jumper is shown in Figure 5.
Refer to Figure 14 below and mount the jumper as desired.
Figure 14. Motion Event Counter Setting Options
3