Download Print this page
Visonic DUET-AM Installation Instructions

Visonic DUET-AM Installation Instructions

Dual-technology microwave/pir intrusion detector

Advertisement

Quick Links

DUET-AM, DUET-AM G3
Dual-Technology Microwave/PIR Intrusion Detector
1. FEATURES
• Combined Fresnel and cylindrical optics improves detection
range and false alarm immunity.
• Look-down "creep zone" lens.
• True Motion Recognition™ (TMR) algorithm (patented) for
recognition of true motion of a human body.
• DRO-stabilized MW microstrip technology.
• MW Motion Simulator simulates the effect of a human body
moving in the MW field (patent pending for MW self-test).
• Range control for adjusting the MW coverage.
• PIR self-test by applying a short heat pulse.
• Temperature compensation for the PIR section.
• Unique tamper protection mechanism.
• Programmable motion event counter (1 or 2 events).
2. SPECIFICATIONS
Input Voltage: 9 to 16 VDC
Current Drain @ 12 VDC: 21 mA standby, 29 mA max.
Low Voltage Detection (DUET-AM G3 only): Below 8.5 VDC
PIR SECTION
Sensor: Low noise dual-element pyroelectric type
Tripping Indication: LED flashes green for up to 5 seconds
Motion Event Verification Counter: Selectable, 1 or 2 events
Front Lens Data (see Figure 2)
Beams: 32 in two layers (10 curtain beams in bottom layer)
Max. Coverage: 20 x 20 m (60 x 60 ft) / 90° field of view
Vertical Adjustment: FAR, MID and NEAR, by sliding the circuit
board along a 3-position scale.
MW SECTION
Oscillator: Microstrip DRO-stabilized Doppler sensor
:
Frequency
10.687 GHz (in the UK only) or 10.525 GHz (10.525
GHz for movement detector is prohibited or restricted from use in
Austria, Czech Republic, Estonia, Finland, French, Germany,
Portugal, Slovak Republic, Turkey, UK, Spain and Sweden).
Detection Range: Adjustable from 25% to 100% (5 m to 20 m)
Tripping Indication: LED lights green for up to 5 seconds
ALARM, TAMPER & TROUBLE DATA
Alarm Indication: LED lights red for 1.3 to 5 seconds if both
sensors trip
Alarm output: Solid State Relay. NC, 100 mA / 30 VDC, 35 ohm
maximum internal resistance. "Open" for 2 – 3 sec. in case of
alarm, masking event (applicable for DUET-AM G3 only) or
complete power failure.
Alarm Duration: 1.3 to 5 seconds
Tamper Switch: N.C., rated at 50 mA resistive / 30 VDC
Trouble output: Solid State Relay. NC, 100 mA / 30 VDC, 35
ohm maximum internal resistance. "Open" in case of auto-
diagnostic failure, Anti-Mask event, low voltage (applicable for
DUET-AM G3 only) or complete power failure.
Masking Detection Delay: About 60 seconds
Trouble/ Masking Indication: LED alternately flashes green and
red and TRB relay opens until the detector is reset.
3. INSTALLATION

3.1 Installation Tips

To minimize false alarms:
Do not aim at heat sources
DE1812
Mount on solid, stable surfaces

Installation Instructions

• Simple-to-use, three-position
vertical adjustment.
• TEST input to enable/disable
the walk test LED remotely
(per new European standard).
• Relay output for trouble.
• Anti-masking protection.
• White light protection.
• Optional swivel brackets for
wall or ceiling installation.
• DUET-AM
G3
has
back
tamper
switch
and
low-
voltage detection.
MOUNTING
Form: Surface or corner (no
brackets); surface, corner and
ceiling with brackets
Height: 2 - 2.6 m (6.5 - 8.5 ft)
without bracket, 2 - 3.6 m (6.5 -
12 ft) with bracket.
Note:
Mounting
heights
greater than 2.6m (8.5 ft) may
reduce the detector's coverage
range.
Caution: with brackets in use,
effective detection ranges may
differ from those indicated in
Figures 2 and 8.
Optional
Brackets:
BR-1
(surface), BR-2 (corner) and
BR-3 (ceiling).
ENVIRONMENTAL
RFI Protection: >30 V/m up to
1000 MHz.
Operating Temperatures: -10°C to 50°C (14°F to 122°F).
Storage Temperatures: -20°C to 60°C (-4°F to 140°F).
Standards: Complies with Part 15 of the FCC Rules.
EN 50131-1 Grade 2 (Grade 3 for DUET-AM G3) Class II, EN
50131-2-4.
This device complies with the essential requirements and provisions of
Directive 1999/5/EC of the European Parliament and of the Council of
9 March 1999 on radio and telecommunications terminal equipment.
See frequency restriction under "Frequency", at the left side.
PHYSICAL
Dimensions (H X W X D): 123 x 76 x 48 mm (4-13/16 x 3 x 1-7/8 in.)
Weight: 145 g (4.5 oz).
PATENTS
U.S. Patents 5,237,330 and 5,693,943
Do not expose to air drafts
Figure 1. General View
TOP VIEW
90°
of
SIDE VIEW ("FAR" POSITION)
2 m
UPPER LAYER
CURTAINS
0
5
10
15
15
30
45
Figure 2. Coverage Pattern
Do not install outdoors
20 m
60 ft
1

Advertisement

loading

Summary of Contents for Visonic DUET-AM

  • Page 1: Installation Instructions

    Standards: Complies with Part 15 of the FCC Rules. Alarm output: Solid State Relay. NC, 100 mA / 30 VDC, 35 ohm EN 50131-1 Grade 2 (Grade 3 for DUET-AM G3) Class II, EN maximum internal resistance. "Open" for 2 – 3 sec. in case of 50131-2-4.
  • Page 2 2 meters apart. D. Do not install the DUET-AM in places where one of the two sensor POINTER circuits alarms constantly or intermittently, due to environmental interference.
  • Page 3 PC board (refer to Figure 4). Three positions lights red for 1.3 to 5 seconds). are available - FAR, MID and NEAR. All new DUET-AM units are set D. When done, disable the LED by setting set switch SW-2 to to the FAR position.
  • Page 4 – Consult the dealer or an experienced radio/TV technician. WARRANTY Visonic Limited (the “Manufacturer") warrants this product only (the "Product") to the original purchaser only (the However, if the Manufacturer is held liable, whether directly or indirectly, for any loss or damage arising under this “Purchaser”) against defective workmanship and materials under normal use of the Product for a period of twelve...