EXTERNAL READER CONNECTION

External Reader Connection
Mon 01 / 01 / 2010
10 : 30 : 20
1
2
3
F 1
4
5
6
F 4
7
8
9
F 7
0
ESC
ENT
F10
GND
Black -
Red +
DC+12V
- Proximity Reader Connection
1.
Connect the DC 12V(+) line of the power supply unit to the plus (+) line of the reader.
2.
Connect the GND(-) line of the power supply unit to the minus(-) line of the reader
3.
Connect the Wiegand data input line 0 of the proximity reader to the pink line
4.
Connect the Wiegand data input line 1 of the proximity reader to the sky blue line
For a list of compliant readers (external readers), see the followings:
SSA-S30X0
- Standard 26bit Wiegand format proximity reader
- Standard 26bit Wiegand + 8bit Burst format proximity/keypad reader
SSA-S30X1
- Standard 34bit Wiegand format proximity reader
- Standard 34bit Wiegand + 8bit Burst format proximity/keypad reader