TECHNICAL SPECIFICATION
(Fig. 1)
TECHNICAL DATA
Height
Width
Depth of the corpus
Weight without casing
Weight with stone casing
Smoke tube pipe diameter
Heating performance range
Room
heating
capacity
dependent on house insulation
Fuel consumption
Pellet container capacity
Power supply
Average
electrical
power
consumption
Fuse
Efficiency
CO
content
2
CO emission re. 13% O
Dust emissions
Exhaust air mass flow
Exhaust air temperature
Chimney draft requirement
The owner of the small heating system or the
authorised person for the small heating system must
keep the technical documentation in a safe place
and present it to the local authority or the chimney
sweep if required.
1. PACKAGING
Your first impression is important to us!
The packaging for your new stove provides excellent
protection against damage. However damage to the
stove and accessories can occur during transport.
mm]
1030
[mm]
520
[mm]
606
[daN]
132
[daN]
205
[mm]
100
[kW]
2,4 - 8
(m3)
[m3]
50-210
[kg/h]
0,6-1,9
[kg]
32
[V]; [Hz]
230; 50
[W]
ca. 100
[A]
1,6 T
[%]
94,5
[%]
10,7
[mg/Nm3]
74
[mg/Nm3]
22
[g/s]
5,5
[° C]
100,3
[Pa]
0
- 8 -
SPARE PARTS - OVE RVIEW
(Fig. 3 - Fig. 7)
DESCRIPTION
01 Fire door
02 Fire door seal
03 Fire door glass
04 Upper temperature limiter
05 Ignition element
06 Conveyorscrew complete
07 Centring plate
08 Motor plate
09 Hexagonal bolt
10 Conveyor screw drive motor
11 Air sensor
20 Internal control unit
21 Main fuse
22 Main board
23 Remote fixed network board (optional)
30 Wing nut
31 Flue gas shaft cleaning lid
32 Intermediate bottom
33 Top/bottom cleaning lid
34 Exhaust gas fan housing
35 Exhaust gas fan motor
36 Hexagonal screws
37 Low temperature switch
38 Smoke tube adapter 100 mm
39 Fire door hinge
40 Container lid (with rating plate, warning sign)
41 Rear wall
42 Side cladding rear right complete
43 Rear wall cover
44 Mains cable with earthed plug
45 Right panel
46 Front cladding bottom
47 Front cladding top
48 Left panel
49 Rear left panel complete
50 Lamination cover complete
Therefore please check that your stove is undamaged
and that all parts are there on receipt! Report any
defects to your stove dealer immediately!
- The packaging for your new stove generally has no
effect on the environment. The box and the film (PE)
can be safely taken to the local council waste
disposal depot for recycling.

Hide quick links: