AccuPower AccuManager 807 Operating Manual

Balance charger/discharger for nicd/nimh/lithium/pb batteries

Advertisement

Quick Links

AccuPower
AccuManager 807
Balance CHARGER/DISCHARGER
FOR NICD/NIMH/LITHIUM/PB BATTERIES
Operating Manual
Thank you for purchasing the AccuManager 807. This is a rapid
charge/discharger with built in balancer, computerised with micr-
oprocessor and specialised operating software. Please read this
entire operating manual completely and attentively before using.

Advertisement

Table of Contents
loading

Summary of Contents for AccuPower AccuManager 807

  • Page 1 Balance CHARGER/DISCHARGER FOR NICD/NIMH/LITHIUM/PB BATTERIES Operating Manual Thank you for purchasing the AccuManager 807. This is a rapid charge/discharger with built in balancer, computerised with micr- oprocessor and specialised operating software. Please read this entire operating manual completely and attentively before using.
  • Page 2 Features Optimised operating software When charging or discharging, A P 8 0 7 has an ‘AUTO’ function that sets the feeding current automatically. Especially for Lithium batteries, it can prevent the over-charging can lead to an explosion by users fault. Every program in the unit is controlled with mutual links and communication for every possible error so it introduces a maximum safety.
  • Page 3 Auto-charge current limit: When charging NiCd or NiMH at ‘AUTO’current mode, you can set the upper limit of change current to avoid from high current charging. This is very useful when charging the low impedance and small capacity NiMH battery in “AUTO’mode. Capacity limit: The changing capacity always calculated by multiple of the charging current and time.
  • Page 4: Exterior Of The Unit

    Exterior of the unit Lithium balance charge program connection diagram WARNING It will damage the charger if you connect your battery with the AP807 incorrectly. The B- Connector is on the mostly right Pin at all 6 balancing plugs.
  • Page 5: Warnings And Safety Notes

    Warnings and safety notes supply. If any malfunction is observed immediately terminate the process and refer to the operation manual. vibration. Do not drop it. head-resistant, non-inflammable and non-conductive surface. Never place them on a car seat, carpet or similar. Keep all the inflammable volatile materials well away from operating area.
  • Page 6 Do not connect more than one battery pack to the charge lead at any one time. Do not attempt to charge or discharge the following types of battery. Battery pack, which consists of different types of cell (including different manufacturers). -Battery, which is already fully charged or just slightly discharged.
  • Page 7 -Do not attempt to disassemble the battery pack arbitrarily. -You have to pay attention to verify the capacity and the voltage of the Lithium battery pack. It may be composed of parallel and series connection mixed. In parallel link the capacity of the battery pack is multiplied by the number of cells but the voltage remains same.
  • Page 8: Program Flow Chart

    Program flow chart PROGRAM SELECT LiXX LiXX CHARGE LiXX CHARGE LiXX BALANCE LiXX BATT FAST CHG LiXX LiXX STORAGE DISCHARGE NiMH PROGRAM SELECT NiMH CHARGE NiMH CHARGE NiMH CYCLE DISCHARGE NiMH BATT Nicd PROGRAM SELECT Nicd CHARGE Nicd CHARGE Nicd CYCLE DISCHARGE Nicd BATT PROGRAM SELECT...
  • Page 9: Initial Parameter Set Up (Users Set Up)

    Initial Parameter set up (Users set up) A P 8 0 7 will be operated with the default value of the essential user settings when it is connected to a 12V batttery for the first time.The screen displays the following information in sequence and the user can change the value of parameter on each screen.
  • Page 10 This shows the trigger voltage for automatic charge termination of NiMH and NiCd battery. The effective value ranges from 5 to 20mV per cell .if the trigger voltage is set higher, there is a danger of overcharging the battery; if it is set lower, there is a possibility of premature termination.
  • Page 11: Lithium Battery(Lilo/Lipo/Life)Program

    This program sets the maximum charge capacity that will be supplied to the battery during charge. If the delta-pack voltage is not detected nor the safety timer expired by any reason, this feature will automatically stop the process at the selected capacity value. The beep sounds at every time pressing the buttons to confirm your action.
  • Page 12: Charging Lithium Battery At Balance Mode

    Charging Lithium Battery The left side of the first line shows the type of battery you select at the users setting. The value on the left side of second line sets a charge current and the value on the right side of second line sets the voltage of the battery pack. After setting the current and voltage press Start/Enter key for more than 3 seconds to start the process.
  • Page 13 After setting the current and voltage press Start/Enter key for more than 3 seconds to start the process. (Charge current:0.1~7.0A, Volatge:1~8series) This shows the number of cells you set up and the processor detects. ‘R:’ shows the number of cells found by the charger and ‘S:’...
  • Page 14 ‘ STORAGE ’ control Lithium battery This is for charging or discharging Lithium battery not to be used for the time being. The program will determine to charge or discharge the battery to the certain voltage depending on the voltage of the battery at its initial stage.
  • Page 15: Nimh/Nicd Battery Program

    Voltage balancing and monitoring during the discharge The processor monitors the voltage of individual cells during ‘storage-mode’ and ‘discharge’ of Lithium battery pack. It tries to normalise the voltages to be equal. For this feature, the individual plug of the battery pack should be connected to the individual port of the charge.
  • Page 16: Discharging Nicd/Nimh Battery

    impedance and small capacity can lead to the higher charge current by the processor at automatic charge mode. But in‘Man’ mode, it will charge the battery with the charge current you set at the display. Each mode can be switched by pressing INC and DEC button simultaneously when the current field is blinking.
  • Page 17: Charging Pb Battery

    stop process, press Batt type/Stop key once. You can change the discharge or charge current by pressing Start/Enter key once during the process. The audible sound indicates you the end of process. At the end of the process, you can see charged or discharged electric capaci- ties of the battery at each cyclic process.
  • Page 18: Save Data Program

    The screen displays the state of charging process. To stop charging forcibly, press Batt type/Stop key once. The audible sound indicates you at the end of process. Discharging Pb battery Set discharge current on the left and final voltage on the right. The discharge current ranges from 0.1 to 5.0A.
  • Page 19: Load Data Program

    with the battery type you set up. The example shows the battery pack of NiMH, 12cells and 3000mAh of capacity. Set up the charge current for manual charge mode, or the current limit for automatic charge mode. Each mode can be switched by pressing INC and DEC button at the same time when the current field is blinking.
  • Page 20: Various Information During The Process

    Various information during the process You can inquire various information on LCD screen during charging or discharging process. When you press DEC button the charger shows the establishment of user settings. And also you can monitor the voltage of individual cell by pressing INC button when the individual connection cable is linked to the Lithium battery being processed.
  • Page 21: Warning And Error Messages

    Warning and error messages AP807 incorporates a various functions of protective and monitoring the system to verify functions and the state of its electronics. In any case of occurring error, the screen displays the cause of error that is self- explanatory with audible sound. The output is connected to a battery with incorrect polarity.
  • Page 22: Specifications

    Specifications Operating voltage range: 10.0~18.0Volt Circuit power: max.150W Charge current range: 0.1~7.0A Discharge current range: 0.1~5.0A Current drain for balancing Li-po: 300mAh/cell NiCd/ NiMH battery cell count: 1~27cells Lithium battery cell count: 1~8Series Pb battery voltage: 2 to 36V Weight: 700g Dimension: 165×130×45mm...