Maximum Power Input Limitation Setting

Warning
Always shut off the power supply breaker before starting.
• The Maximum Power Input Limitation needs to be set when the unit is installed.
• This function limits the power input of the unit to 1700W.
• It is recommended for locations with low-capacity circuit breakers.
Caution
This function is only for the 2MKS40 and 2AMKS40.
• Set as follows.
1) Remove the three screws on the side and remove the top of the outdoor unit.
2) Remove the fan motor lead wire from the hook and loosen it.
3) Disengage the four tabs marked with a triangle and remove the electrical cabinet.
4) Cut the jumper (J9) of the Printed circuit board inside.
5) Go back through step 3) → 2) → 1). Make sure all components are well secured when doing this.
Fan motor lead wire
2) Remove the fan motor lead
IEnglish
1) Remove the three screws.
Hook
wire from the hook.
4) Cut J9
Top plate
3) Disengage the four tabs.
Electric box
Printed circuit board