Cleaning and care

Changing a lamp

The halogen lamps become very hot
during operation.
They can cause burns even after
being switched off for some time.
Allow them to cool down for a few
minutes before changing them.
 Disconnect the rangehood from the
mains electrical supply before
replacing the lamps (see "Warning
and Safety instructions").
22
 Remove the grease filters.
 Loosen the lamp's securing screw a
little.
 Slide the screw and the lamp
downwards.
 Then tighten the screw again.
 Turn the halogen lamp anti-clockwise
and pull it out.
 Replace it with a new lamp of the
same type: GU/GZ 10, 230 V, 50W.
Refit the lamp by reversing the steps
shown above. Please observe
manufacturer's instructions.
 Refit the grease filters.