Reset Button - Siemens SCALANCE XB-200 Operating Instructions Manual

Hide thumbs Also See for SCALANCE XB-200:
Table of Contents

Advertisement

Description of the device

2.3 RESET button

2.3
RESET button
Position
The "RESET" button is located on the rear of the SCALANCE XB-200.
Figure 2-1
Resetting the device to factory defaults
Note
Damage to the button
The RESET button is a short-stroke button with only a slight pressure point. To operate the
button, you only need a force 2.5 N (approx. 250 g).
To avoid damaging the button press it with little force. Hold the tool you are using, for
example, with only two fingers.
Note
If you reset, all the changes you have made will be overwritten by factory defaults.
To reset the device to the factory defaults, follow the steps below:
1. Press the "RESET" button with only slight force.
A screwdriver for example with following size is suitable:
– Blade thickness 0.8 - 1.8 mm
– Blade width 4.0 - 4.8 mm
2. Hold down the button for approximately 12 seconds.
After 9 seconds, the fault LED "F" flashes for 3 seconds.
– If you release the button after approximately 12 seconds, the device is restarted and
– If you release the button before the 12 seconds have elapsed, the reset is canceled.
16
Position of the "RESET" button, for example on the SCALANCE XB213-3
the factory settings are restored.
Operating Instructions, 09/2015, C79000-G8976-C359-03
SCALANCE XB-200

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance xb-208Scalance xb205-3Scalance xb213-3

Table of Contents