Operating Your Boiler - Dunkirk PVWB Installation Instructions Manual

Series 2 gas-fir gas-fired hot-water boilers
Table of Contents

Advertisement

Continuous Pilot Boiler - VR8200A/VR8300A Gas Valve Operating Instructions
1. STOP! Read the safety information on page 16.
2. Set the thermostat to lowest setting.
3. Turn off all electric power to the appliance.
4. Remove lower front panel.
5. Rotate gas control knob slightly and turn clockwise
to "OFF"
6. Wait five (5) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP! Follow
"B" in the safety information on page 19 If you don't smell
gas, go to next step.
7. Find pilot - follow metal tube from gas control. The pilot is
between two burner tubes as shown in Fig. 14 on page 18.
8. Turn knob on gas control counterclockwise to
"PILOT"
AUTOMATIC GAS VALVE
The Automatic Gas Valve opens or closes according to the
heat requirements of the thermostat and temperature limit
control. It closes if the pilot goes out. Each individual control
must be operating correctly before any gas can pass to the
burners. Any one control can hold the gas supply from burner
regardless of the demand of any other control.
SAFETY PILOT
Safety Pilot prevents the flow of gas to burner if the pilot goes
out, or will not ignite.
GAS VALVE SAFETY SHUTDOWN TEST
1. For boilers equipped with continuous pilot, with main burners
firing, disconnect the thermocouple from the gas valve. The
gas valve should immediately shut off the main burners and
the pilot.
2. For boilers equipped with intermittent ignition, with main
burners firing, disconnect the ignition cable from the
intermittent pilot control box. The gas valve should shut off
the main burners.
TURN OFF ELECTRIC POWER
reconnecting ignition cable, to prevent electric shock.
9.
10. After pilot remains lit when red reset button is released,
11. Replace lower front panel.
12. Turn on all electric power to the appliance.
13. Set thermostat to desired setting.
TO TURN OFF GAS TO APPLIANCE
1.
2.
3.

Operating Your Boiler

RELIGHT
The electric and gas shall be off for 5 minutes before relighting.
THERMOSTAT
Keep it set at a desired room temperature. If windows are to
be opened or heat is not needed, move thermostat pointer to a
lower setting.
Safe lighting and other performance criteria were met with
the gas manifold and control assembly provided on the boiler
to boiler before
when the boiler underwent tests specified in ANSI Z21.13 -
latest revision.
17
Rotate the gas control knob counterclockwise
to "PILOT" Push down and hold the red reset button while
you light pilot burner with a match.
After about one minute, release reset button. Pilot should
remain lit. If it goes out, turn gas control knob clockwise
to OFF To relight, repeat steps 5-9.
• If button does not pop up when released, stop and
immediately call your service technician or gas supplier.
• If the pilot will not stay lit after several tries, turn the gas
control knob to "OFF" and call your service technician or
gas supplier.
turn gas control knob counterclockwise to "ON."
Set the thermostat to lowest setting.
Turn off all electric power to the appliance if service is to
be performed.
Push in gas control knob slightly and turn clockwise
to "OFF" Do not force.
In the event of failure of any component, the system will not
operate or will go into safety lockout. The system is
completely self-checking. On every call for heat, each
component must be functioning properly to permit operation.
On safety lockout the system has to be reset by turning the
thermostat to the lowest setting for one minute, then back
to the normal setting.