Audible Alarm - Aqua Lung i450T Owner's Manual

Table of Contents

Advertisement

DIVE FEATURES

AUDIBLE ALARM

While operating in Dive or Gauge Mode, the audible alarm will emit 1 beep per second for 10 seconds when
alarms strike, unless it is set to Off. During that time, the audible alarm can be acknowledged and silenced by
pressing the SELECT button.
An LED warning light, on the side of the housing, is synchronized with the audible alarm and flashes as the au-
dible alarm sounds. It will turn off when the alarm is silenced. The audible and LED alarms will not be active if the
audible alarm is set to OFF (a Set Alarms setting).
Free Dive Modes have their own alarms which emit multiple beeps multiple times which cannot be acknowledged
or set to OFF.
Events that emit (10) beeps >> each sound for ½ sec with ½ sec silence between beeps:
• Watch Daily Alarm.
• Watch CDT Alarm.
• DIVE, GAUGE - GTR Alarm.
• DIVE, GAUGE - Turn Alarm (TMT 1).
• DIVE, GAUGE - Press Alarm (TMT in use).
• DIVE, GAUGE - Loss of Link (Dive Mode).
• DIVE, GAUGE - Ascent Rate too fast.
• DIVE, GAUGE - Depth Alarm.
• DIVE, GAUGE - EDT Alarm.
• DIVE - DTR Alarm.
• DIVE - N2 Alarm.
• DIVE - entry into Decompression.
• DIVE - Conditional Violation.
• DIVE - Delayed Violations 1, 2.
• DIVE, GAUGE - Delayed Violation 3.
• DIVE, GAUGE - entry into Violation Gauge Mode.
• DIVE - PO2 Warning and Alarm.
• DIVE - O2 Warning and Alarm.
• DIVE - Gas Switch Alarm.
Events that emit (3) beeps >> each sound for ½ sec with ½ sec silence between beeps:
• DIVE, GAUGE - Ascent Rate warning.
• FREE - Delayed Violation 3.
Events that emit (3) sets of (3) beeps >> each sound for ½ sec with ½ sec silence between beeps and ½ sec
silence between sets:
• FREE - SRT Alarm.
• FREE - RDI Alarm. RDI does not alarm at the DA alarm depths.
• FREE - CDT Alarm.
• FREE - N2 Alarm.
• FREE - Violation, entry into Decompression.
Events that emit (3) sets of (3) beeps >> each sound for ⅛ sec with ⅛ sec silence between beeps and ¼ sec
silence between sets:
• FREE - DA1 to DA3 Alarms.
Events that emit (2) beeps >> each sound for 1 sec with ½ sec silence between beeps:
• FREE - RTI Alarm.
23
© Aqua Lung International, Inc. (2015)
Doc. 12-7834-r04 (2/16/16)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents