CAUTION: Label all wires before disconnecting for servicing. Proper polarity must be
observed so the furnace motor will run with the proper direction of rotation to insure correct
air delivery.
I
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors
can cause improper and dangerous furnace operation.
You, as the owner/user, should insect the furnace monthly during the heating season for presence of
soot on vent. Operating the furnace under this condition could lead to serious property damage,
personal injury or loss of life. If soot is observed on the vent, immediately shut furnace down and
contact a qualified service agency.
Listed below are several safety related items that you should follow during the heating season to
assure continued safe operation of the furnace.
1. Inspect furnace venting. Venting must be free of obstructions, void of soot and properly
terminated to the atmosphere. (Refer to installation manual.)
I
WARNING: Do not install screens over the vent for any reason. Screens will become
restricted and cause unsafe furnace operation. Accessories are being marketed for
RV products which the manufacturer does not recommend. For your safety, only
factor authorized parts are to be used on your furnace.
2. Periodically inspect the vent for obstructions or presence of soot. Soot is formed whenever
combustion is incomplete. This is your visual warning that the furnace is operating in an
unsafe manner. If soot is present, immediately shut furnace down and contact your dealer or
a qualified service person.
3. Periodically observe the main burner flame to assure it is burning with a hard blue flame with
well defined burner ports. (Fig. 7-5) If flame
appears yellow yellow or burner has a lazy flame,
shut furnace down. It is possible that burner
needs cleaning or replaced. If excessive rust and
corrosion are present on burner surface, the burner
must be thoroughly cleaned or replaced. The
burner may be cleaned using a steel wire brush
and blown clean using high compression air.
Contact a qualified service person for assistance.
NOTE: To properly observe burner operation, the
furnace must be removed. This should only
be done by your dealer or a qualified service agency.
4. Keep furnace clean. More frequent cleaning may be required due to excessive lint from
carpeting, bedding material, etc. It is imperative that control compartments, burners and
circulating air passageways of the appliance be kept clean.
5. The motor is permanently lubricated and requires no oiling.