Electrical Connections; Spare Parts - OSO Wallsmart W 30 User Manual And Spare Parts List

Table of Contents

Advertisement

Available languages

Available languages

Electrics – spare parts
m
t
emperature regulator
T85
TYPE
-
+
RTS PLUS
16A 250V~
PATENTED
MADE IN
ITALY
N
2
2
L
1
N
L
1
THERMOWATT
m
1.5
ainS CaBle
l = 2,5
m
t
.
emp
SenSor
e
.
leC
ContaCt
t
hermoStat
70°C
adjuStaBle max

Spare parts

product
Forandringer forbeholdes • Ändringar kan förekomma • OSO reserves the right to make changes without notice • Возможны изменения без предварительного уведомления.
anual reSet Button
t
hermoStat
e
2
W
lement
K
e
arthed to
ConneCtor
on tanK
p
lug
earthed
²
mm
.
S
enSor Sheath
o-
ring Seal
e
2
W 230 v 1-
lement
K
part type
Mixing/safety valve
Thermostat
El. box cover assembly
Element
Element spanner

Electrical connections

The mains cable with plug is factory connected and fitted. It
just has to be plugged into a 230 V/10 A earthed socket. NB:
The heater must be filled with water before the power is con-
nected. If the heater is not filled, the element will be destroyed
and the warranty will be invalidated. For further information on
the thermostat and element, see spare parts.
Replacing the thermostat:
Disconnect the power before taking the electrical cover off
the heater. Disconnect the two power supply conductors (blue
and brown) from the thermostat. The earth conductor (yellow/
green) is attached to a connector on the tank. The thermostat is
pressed firmly onto the element. It is simple to remove by pull-
ing it straight off the element, which is screwed into the heater.
NB: The thermostat has a sensor that goes into a sensor sheath
on the element. When a new thermostat is fitted, the sensor
has to be inserted in the sensor sheath. Then press the thermo-
stat firmly into place before reconnecting the conductors.
Replacing the element:
Turn off the water supply and drain the heater completely us-
ing the drain plug. Remove the thermostat as described above.
Then unscrew the element using a 1½" element spanner (KN)
and screw a new element in (check that the o-ring seal is in
place on the element) before putting the thermostat back.
NB: The heater MUST be filled with water before the power is
connected!
- 5/4"
phaSe
part description
FTU 60°C / 9 bar
For undermounting
Integral shut-off/check valve
RTS3 with insertion sensor. Adjustable
up to 70°C. 16 A 250 V~
El. box cover complete with cable, plug,
o-ring seal and LED light
Pipe thread 5/4" 2 kW 230 V 1-phase
Single element with sensor sheath
Length 300 mm
KN 1½", for element (above)
The thread is 5/4", but the element head is 1½ ".
part number
90240
801 5896
801 5171
801 5139
801 5317
7