Sensor Model 2100ARFT
Document Number: 466-1747 Rev. C
September 2000
Product Summary
The System Sensor Smoke Sensor Model 2100ARFT
(smoke alarm) is a Learn Mode, wireless, photoelectric
smoke sensor with a self-contained alarm siren, a low-bat-
tery annunciator, and a status light. The smoke alarm is part
of a security/fire alarm system and communicates with the
system control panel.
Each smoke alarm uses two 3-volt lithium batteries. The
batteries are shipped in the unit with a pull tab inserted at
the positive terminal. Remove the pull tab and reinstall the
batteries as needed, observing correct polarity.
The detector provides the following features:
Fixed/rate of rise 135° F temperature heat detector
trips an alarm when the temperature reaches 135° F or
higher, or when the temperature rises rapidly.
Freeze detector sends a trouble signal when the ambi-
ent temperature around the detector drops below 40° F.
This could indicate a heating problem on the premises.
System sirens sound trouble beeps, and if the condition
continues for one hour, the panel reports to central
monitoring station.
Note
Freeze detector only compatible with Concord™ , Con-
cord Express™ , Ultragard
®
Simon
systems will only respond on site with trouble
beeps and will not report the trouble condition to the
central monitoring station.
Installation Guidelines
This equipment should be installed in accordance with
the National Fire Protection Association's Standard 72
and/or Standard 74 (National Fire Protection Associa-
tion, Batterymarch Park, Quincy, MA 02269).
Avoid installing the unit until all construction is com-
pleted. The mounting ring may be pre-installed.
Leave the orange dust cover on the unit until sheet
rocking and sanding are completed; otherwise, dust can
get into the unit and cause false alarms.
Note
The orange dust cover must be removed for the unit to
detect smoke.
System Sensor™ Smoke Sensor Model 2100ARFT
®
®
, and Advent
systems.

Installation Instructions

CAUTION
Not compatible with CareTaker
versions with software versions 3.0 or earlier.
Not compatible with Commander
versions with software versions 4.0 or earlier.
Equipment Needed
Phillips screwdriver.
Pocket-sized slotted screwdriver.
Programming
This section describes the basic steps for adding the sensor
to panel memory. For more detailed programming informa-
tion, refer to the specific panel installation instructions.
Figure 1. Mounting Bracket
To add the smoke alarm to panel memory:
1.
Put the panel in Program Mode/Learn Sensors.
2.
Select a sensor group and sensor number.
3.
Remove mounting bracket to trip tamper.
4.
The panel will indicate that the sensor has been
learned.
5.
Exit from program mode.
Note
Reinstall smoke unit on mounting bracket. This
restores the tamper to normal—it may take the micro-
processor in the smoke unit up to 12 seconds to
restore the tamper.
Mounting Guidelines
Selecting a suitable location is critical to the operation of
smoke alarms/detectors. This equipment should be installed
ITI Part No. 60-838-95, 60-838-95R
®
Plus and custom
®
2000 and custom
1

Advertisement

loading

Summary of Contents for System Sensor 2100ARFT

  • Page 1: Installation Instructions

    Not compatible with CareTaker Plus and custom versions with software versions 3.0 or earlier. ® The System Sensor Smoke Sensor Model 2100ARFT Not compatible with Commander 2000 and custom (smoke alarm) is a Learn Mode, wireless, photoelectric versions with software versions 4.0 or earlier.
  • Page 2 Put a smoke alarm in the hallway outside of every bed- room area. A minimum of two smoke alarms are required in homes with two bedroom areas. System Sensor™ Smoke Sensor Model 2100ARFT...
  • Page 3 Refer to the specific panel installation instructions for Smoke alarms cannot detect smoke in chimneys, walls, details. System Sensor™ Smoke Sensor Model 2100ARFT...
  • Page 4: Maintenance

    Emphasize that everyone should escape as quickly as batteries are low. possible. Do not stop to gather any belongings. Crawl and hold your breath as much as possible to help reduce smoke inhalation during your escape. System Sensor™ Smoke Sensor Model 2100ARFT...
  • Page 5: Floor Plan Example

    BEDROOM DINING In family living units with more than KITCHEN BEDROOM ROOM ROOM one sleeping area, locate a smoke BATH detector at each area. LIVING ROOM BEDROOM BEDROOM Figure 10.Examples of a floor plans. System Sensor™ Smoke Sensor Model 2100ARFT...
  • Page 6 Emergencies Draw you floor plan in this space. System Sensor™ Smoke Sensor Model 2100ARFT...
  • Page 7: Troubleshooting

    ITI Advent, CareTaker, Commander, UltraGard, Quik Bridge, and Simon are registered trademarks of Interactive Technologies, Inc. Concord, Con- cord Express, and Learn Mode are trademarks of ITI. System Sensor is a trademark of System Sensor. System Sensor™ Smoke Sensor Model 2100ARFT...