The Mirage Direct Vent Gas Insert installation and venting
must conform to the current CAN/CGA-B149 installation
code (in Canada) or the National Fuel Gas Code, ANSI
Z223.1 -1988 (in the USA), and approved per local codes.
Only qualified (licensed or trained) personnel should
install this product.
Existing Fireplace
(Masonry or Factory Built)
The Mirage Direct Vent Gas Insert is designed to be installed
into a masonry or a factory built zero clearance fireplace. The
masonry fireplace must be built according to the require-
ments of the standards for chimneys, fireplaces, vents and
solid fuel burning appliances, NFPA 211 (Latest Edition) or
applicable National, Provincial, State or local codes. The
factory built zero clearance fireplace and its chimney must be
certified and meet applicable National, Provincial, State or
local codes.
f i r e - p a r t s . c o m
In order to sufficiently accommodate the Mirage Direct Vent
Gas Insert, the minimum size of the fireplace should be 28-3/
8 inches wide, 20-3/4 inches high and 15 inches deep (see
Fig.#2).
The fireplace and its chimney should be swept and inspected.
The existing fireplace damper (if present) should be locked
open or removed completely if the opening is too small for
two - 3" flue liners to pass through.