Optional Blower

Electrical Supply:
Circulating air blower electrical rating: 115V, 60
Hz, 80 watts. (Fig #25) For your protection against
shock hazard, use only a properly grounded outlet
that will accept a three-pronged plug. Do not cut or
remove the grounding prong.
Consult local codes or, in the absence of local
codes, with the current CSA C22.1 Canadian Elec-
trical Code and in the USA with the National
Electrical Code, ANSI/NFPA 70 (latest Edition).
Installation:
The blower kit must be installed before the burner
assembly is in place. Unpack and inspect blower
kit.
1) Position the blower onto studs located at the
rear of the appliance and secure in place with
wing nuts provided. (Fig. #26)
2) Place the speed control junction box temporar-
ily in the right front corner of the appliance. The
f i r e - p a r t s . c o m
junction box attaches to the underside of the
burner assembly, once in place. (Fig. #27)
3) Feed the power cord out through the plastic
grommet on the side of the appliance.
Fig. # 25
Rocker
Snap Disc
Switch
Switch
Speed
Control
Fig. # 26
Fig. # 27
115 Volts
60 Hz
Operation:
0.5 Amperes
The circulating air blower is thermostatically controlled to
turn on automatically once the unit is at operating tempera-
ture. A few minutes after the appliance is lit, with the variable
Blower
speed control set at a desired setting, the blower will auto-
matically turn on. The blower will automatically turn off a
few minutes after the appliance is shut down.
The blower may also be operated manually. Push the rocker
switch to manual position and the blower will operate inde-
G (green)
pendent of the burner provided the variable speed control is
L1 (white)
set.
L2 (black)
Optional Blower
Studs
15