GAS SUPPLY

The Mirage Gas Appliance comes equipped with a flexible 3/8" N.P.T.
Male inlet for easy gas connection. This connector is located behind the
left side panel.
Correct gas pressure requirement:
Min. Pressure
(For purpose of input adjustment)
Max Pressure
Manifold Pressure
Proper gas line diameter must be used to assure proper operation. A
pressure test port (1/8 inch N.P.T. plugged tapping) must be provided
for checking gas pressure. This port must be located immediately
upstream of the gas supply connection to the appliance.
f i r e - p a r t s . c o m

ELECTRICAL

No electrical connection is required for the gas system operation. The
self generating pilot provides current for the optional remote wall switch
or wall thermostat. (See fig. # 4 for proper installation.)
Circulating air blower electrical rating: 115V, 60HZ, 80 watts. (See Fig.
# 7 for blower wiring diagram) For your protection against shock hazard,
use only a properly grounded outlet that will accept a three-pronged
plug. Do not cut or remove the grounding prong.
Consult local codes or, in the absence of local codes, with the current
CSA C22.1 Canadian Electrical Code and in the USA with the National
Electrical Code, ANSI/NFPA 70 (Latest Edition)
Fig # 7
BLOWER (part #21 A)
SPEED
SNAP DISC
CONTROL
SWITCH (part #24)

BLOWER OPERATION

The circulating air blower is thermostatically controlled and will not
operate if appliance is cold. A few minutes after the appliance is lit and
the variable speed control set at a desired setting, the blower will
automatically turn on. The blower will automatically turn off a few
minutes after the appliance is shut down.
6
Natural Gas
5.0" wc
10.5" wc
3.5" wc
115 VOLTS
60 Hz
0.5 AMPERES
If any of the original
wire must be replaced,
it must be replaced with
type GTF wire or its
equivalent.
G (green)
L2 (black)
L1 (white)

CLEARANCES

The minimum clearances from the appliance to combustibles are shown
on Fig. # 8. For purpose of servicing, a 12" right side (side with controls)
clearance is recommended. Adequate clearances around air openings
and combustion air supply are required.
Minimum Clearance
to Combustibles
Sidewall to Appliance
Rearwall to Appliance
Corner to Appliance
Fig. # 8
3 in
(76 mm)
1 in.
(25 mm)
1 in.
(25 mm)