Eep-Rom - JVC GY-HM790U Service Manual

Hide thumbs Also See for GY-HM790U:
Table of Contents

Advertisement

5.1.10 OTHERS Menu Operation
(1) Refer to 5.1.2.3 to display the SERVICE MENU.
(2) Move the cursor to [OTHERS], then press the [Set] button or the [Cross-Shaped] button (right).
(3) The OTHERS Menu is displayed.
--- OTHERS ---
ALL RESET
MEM. EDIT
BACK
Refer to 5.1.5 ADVANCED FUNCTION Menu because the operations are almost the same.
Item
ALL RESET CANCEL
Standard setting.
EXECUTE Resets all EEP-ROM data to default settings except adjustment data, hour meter data, and IEEE1394 ID
data.
MEM.EDIT
Contents of the EEP-ROM can be edited directly.
* ADR: Address (0x000-0x9DF) display
* DATA: Display of data embedded in address shown by ADR
Operation procedure
(1) Move the cursor to [MEM.EDIT], then press the [Set] button or the [Cross-Shaped] button (right).
(2) The ADR parameter blinks. Select the address (ADR) to be edited, then press the [Set] button or the [Cross-
Shaped] button (right).
(3) The DATA parameter blinks. Change the data.
(4) Press the [Set] button or the [Cross-Shaped] button (right) to set the parameter. The parameter lights up.
(5) Move the cursor to [BACK], then press the [Set] button or the [Cross-Shaped] button (right) to go back to the upper
layer and finish the setting.
NOTE:
Data that is crucial for the system is stored in the EEP-ROM, and making unadvised changes to it can cause the unit
to stop operating correctly. Please do not use anything other than the IEEE1394 ID setting.
5.2

EEP-ROM

5.2.1 EEP-ROM and maintenance data
GY-HM790 is equipped with four EEP-ROMS for the purpose of data maintenance, and their contents are as per the following list.
When the circuit board or EEP-ROM is replaced, there will be no data in the EEP-ROM. When the unit is turned ON, and the SYSCON
CPU recognizes that there is no data in the EEP-ROM, it automatically writes initial data into the EEP-ROM to initialize it.
The memory data shown in the table below will all be reset to the default settings. It is necessary to perform necessary adjustments
and settings again.
EEP-ROM
Board name
IC10
ISB board
(Camera CPU)
IC1504
CODEC board
(SYSCON CPU)
CANCEL
ADR : 000 DATA : 80
• Blemish data
• Adjusted data (Camera section)
• User menu and Service menu settings data
• Adjustment data
• IEEE1394 ID data
• HOUR METER data
Parameter
Memory data content
(No.HC034<Rev.001>)1-27