REMOVING THE WATER FEED TUBE / TURBOZONE™
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug dishwasher or disconnect power.
2.
Open the dishwasher door.
3.
Remove upper and lower rack out of the
dishwasher.
Spray Arm
4.
Rotate spray arm retainer counterclock-
wise to release spray arm.
Spray Arm Retainer
5.
Upper Spray Arm
6.
Spray Arm
4-4
Remove water feed tube:
a) Remove screw located at the center
back of the tub.
b) Remove one screw located at the top
of the tub near the upper spray arm.
screw
Remove the manifold tubing by rocking the
manifold side to side and front to back.
If necessary, slight outward pressure on
the locking tab will release the manifold.